Meanings Of Error Message Codes - HOMCOM A90-225 Instructions D'assemblage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Meanings of Error Message Codes

Treadmill DC system Error message
E01:Indicate abnormal phenomena of computer and electronic control communication
E01 Solutions to
The communication line of the computer
Common
is not well connected, broken and in bad
Problems
contact.
No Signal Output of computer
No Signal Output of down-control
E02:Indicate abnormal phenomena between down-control and motor
E02 Solutions to
The motor wire is not connected properly
Common
Problems
No Voltage Output or Abnormal Voltage
Output of down-control
Bad motor
E03:Indicates the abnormal phenomenon of the down-control detection speed
E03 Solutions to
Photoelectric inductor incorrectly mounted
Common
on motor (photosensitive mode)
Problems
Poor
(Photosensitive Mode)
Failure or motor damage of down-control
board circuit (non-inductive mode)
E04:Indicate information prompt for overvoltage protection of down-control logging
motor
E04 Solutions to
The treadmill load exceeds the rated
Common
operating voltage of the motor
Problems
Abnormal treadmill motor or excessive
speed due to light sensitivity failure
Failure
Overvoltage Measurement Line
instructions
Photoelectric
Inductor
of
down-control
-24-
Please reconnect the communication line
Replacement of computer to be repaired
Replacement of down-control to be repaired
Check whether the motor wires are connected
correctly
Replacement of down-control to be repaired
Replacement motor
Reassembly
Replacement of Photoelectric Inductors
Replacement of down-control or motor, to be
repaired
Recommended in the rated operating voltage
range of the motor
Replacement of motor or Photoelectric Inductors
Board
Replacement of down-control to be repaired