INSTALLATION MANUAL
CBB
Self-contained Keypad - braille keys
6] PROGRAMMING
Description:
- 1 2V to 24V ac power supply
or 12V to 48V dc.
- 1 2 key keypad with braille keys.
- V isual feedback (Green and Red
LED's)
- N on-volatile EPROM memory.
- 1 00 programmable codes
in 4, 5 or 6 digits.
- 1 relay output N/O contact
6A @ 250V
- 2 relay outputs N/O and N/C
contact 6A @ 250V
- M aster code programmable
in 4, 5 or 6 digits
- W arning buzzer.
- 1 request-to-exit input
- P 2 jumper: Reset to default master
code and delete all user codes
- P 3 jumper: User code modifi cation
by user active
Default values:
- N o code.
- I llumination time: 10 seconds.
- R elay release time: 1 second.
- C ode length: 5-digits.
- M aster Code: 1 2 3 4 5.
- P rogramming security-lag: 120s.
A. Resetting the memory
1. Enter the master code twice.
- F or the fi rst use, the factory
master code is: 1 2 3 4 5.
- R ed LED lights on to confi rm
e ntry in programming mode.
*
2. Then press
6.
- G reen LED lights on for 1 second.
*
- Press
and # to confi rm the resetting.
- G reen LED lights on.
Wait for the lighting to go off.
- T he master code is 1 2 3 4 5 again
and all the codes have been erased.
T he keypad is reinitialised. Red led lights
on, then lights off.
- T he keypad is no longer in the
programming mode and the default values
have been restored.
All manuals and user guides at all-guides.com
- S ub master code for user code
modifi cation User Group 1: *
and #
- S ub master code for user code
modifi cation User Group 2: 1 and 3
- S ub master code for user code
modifi cation User Group 3: 4 and 6
- R ed LED light on when keypad
is powered.
Audible signal correspondence:
- 1 short beep: Keypad powered.
- 1 long beep: Programming
validated and relay activated.
- 2 short beeps: Enter or Exit
from programming.
- 4 short beeps: data computing
error.
Digits used and opening codes:
- A ll the keypad keys can be used
to program a code.
- T he master code and the User
codes can be of 4 or 5 or 6 digit
in length.
- T he master code CAN NOT be used
as a user code.
- C odes 0 0 0 0 0 0, 0 0 0 0 0
and 0 0 0 0 can only be used
to delete a user code. To delete
a User Code enter the user number
(location number) then enter
0 0 0 0 if the code length
is in 4-digit format, enter 0 0 0 0 0
if the code length is in 5-digit format.
Control by push button:
- T he connection of push button P1
is intended for controlling relay 1.
(the mode and the time-lag
can be programmed).
- H 1 input can be used with a timer
to allow free access by pressing
on the O digit key. If the timer
contact is open then the free
access is deactivated. If the timer
is closed then the free access
is activated.
Consumption
(without the control elements)
With the 2 relays controlled:
- I n 12 V ac: 20 mA
in stand-by, 100 mA max
with 3 relays activated
- I n 24 V ac: 10 mA in stand-by,
50 mA max with 3 relays activated
OR
1. Turn off the power supply.
Place a jumper at P2.
2. Turn the power supply on again.
- G reen LED lights on.
Wait a few seconds, a beep is emitted.
- G reen LED lights off.
Remove the jumper at P2.
3. The master code is 1 2 3 4 5 again
and all the codes have been erased.
The default values have been restored.
EN
cdvi.com
15
cdvigroup.com