INSTALLATION MANUAL
PROMI1000PC
One door double technology controller (Proximity and Digicode
1.4] DEFAULT VALUES
- No badge or user code,
- Operating mode: 0 for
badge and user code,
1.5] AUDIBLE SIGNAL CORRESPONDENCE
- 1 short beep = keypad key pressed,
- 1 long beep = Access valid,
1.6] VISUAL SIGNAL CORRESPONDENCE
LED COLOR
Orange flashing
Orange solid
Green solid
Red fixed
2] USING THE CONTROLLER
The key-in keypad time is 10 seconds.
IMPORTANT
The key press is cancelled after that time.
2.1] RESET THE MEMORY
- Put the ST1 jumper in position 2-3.
- The green LED flashes for 5 seconds.
- The master code is retored to the factory default value .
- The LED tuns red and a beep is emitted.
- Remove the jumper from position 2-3 to return to the normal operating mode.
- Keep the jumper in position 2-3 to reset the memory completely.
- The red LED flashes for 5 seconds and then becomes solid.
- The LED stars flashing orange the reset is completed and a beep is emitted.
- Remove the jumper from position 2-3 to return to the normal operating mode.
- Keep the jumper in position 2-3 to reset the memory containing the events.
- The orange led flashes for 5 seconds and then becomes fixed while the memory is clearing the events.
- The LED goes off at the end of the erasing operation.
- Remove the jumper from position 2-3 to return to the normal operating mode.
2.2] TAGS READING
In mode 0 (badge and code)
- Present the tag in front of the unit. A beep confirms that the tag has been read.
- Enter the 5-digit user code. If the user code is valid then the access is granted.
- Two beeps indicate a non valid badge or user code Two beeps indicate a non valid badge or user code.
In mode 1 (Badge only)
- Present the tag in front of the unit. If the badge is valid then the access is granted.
- Two beeps indicate a non valid badge.
cdvi.com
4
cdvigroup.com
- Door release time: 1s,
- Alarm time delay:
00 without alarm,
DURING READING
Standby
Access valid or free access
Alarm active
Alarm active
- Key-in keypad time: 10s,
- Master code: 1 2 3 4 5,
- No schedule,
- 2 short beeps = Tag unknown.
OR
OR
)
®
- No free access,
- No holiday,
- No anti-passback.
DURING PROGRAMMING
Error computing data
Main menu
Valid data computing
Valid entry in menus
EN