CDVI Digicode CBB Manuel D'installation page 17

Masquer les pouces Voir aussi pour Digicode CBB:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
CBB
Self-contained Keypad - braille keys
2. Enter #0 for the key-in keypad time.
- G reen LED lights on for 1 second.
- E nter the duration time in second
E .g. : From 10 for 10 seconds to 99
for 99 seconds
- T he green led lights on to confi rm
the programming.
*
3. Press
1 for output time of relay 1
- G reen LED lights on for 1 second.
- E nter the duration in seconds.
E .g. : From 01 for 1 second to 99
for 99 seconds or enter 00 for a permanent
illumination. The green led lights on
to confi rm the programming.
*
4. Press
2 for output time of relay 2
- G reen LED lights on for 1 second.
- E nter the duration in seconds.
E .g. : From 01 for 1 second to 99
for 99 seconds or enter 00 for a permanent
illumination. The green led lights on
to confi rm the programming.
*
5. Press
3 for output time of relay 3
- G reen LED lights on for 1 second.
- E nter the duration in seconds.
6. Press # to exit from the programming
mode.
The red LED lights off to confi rm
that the keypad is in stand-by
operating mode.
Red LED fl ashing 4 times indicates
a data computing error.
F. Resetting the master code
- I n normal operation, place a jumper at P2
- G reen LED lights on to confi rm
e ntry in programming mode.
2. Enter #0 for the key-in keypad time.
- G reen LED lights on for 1 second.
- A beep is emitted.
- Wait for the green LED to light off.
- Remove the jumper.
All manuals and user guides at all-guides.com
G. Changing the code by the user
H. Setting a sub master code
- T he master code is again 1 2 3 4 5 6
in 6 digits, 1 2 3 4 5 in 5 digits
or 1 2 3 4 in 4 digits.
To enable the function programming
the code by the user place jumper on P3.
Remove the jumper to disable the function.
1. Enter the old user code.
- T he relay is activated.
- G reen LED lights on.
2. Enter the 2-digit sub master code
- T he red LED lights on to authorise
the modifi cation.
3. Enter the new user code.
- G reen LED lights on for 1 second
to confi rm the new code.
- T he red LED lights off.
Check the new user code to be sure
of the modifi cation.
1. Enter the master code twice.
- F or the fi rst use the factory master code
is: 1 2 3 4 5.
- T he red LED's light on to confi rm entry
in programming mode.
*
2. Press
7 to input modifi cation digits
for group 1 user codes.
- G reen LED lights on for 1 second.
- E nter the two digits of the modifi cations.
*
3. Press
8 to input modifi cation digits
for group 2 user codes.
- G reen LED lights on for 1 second.
- E nter the two digits of the modifi cations.
*
4. Press
9 to input modifi cation digits
for group 3 user codes.
- G reen LED lights on for 1 second.
- E nter the two digits of the modifi cations.
5. Press # to exit from the programming mode.
The red LED lights off to confi rm that the
keypad is in stand-by operating mode.