INSTALLATION MANUAL
CAA - CBB
Self-contained Keypads - braille keys
6] PROGRAMMING
Description:
- 12V to 24V ac power supply
or 12V to 48V dc.
- 12 key keypad with braille keys.
- Visual feedback (Green and Red
LED's)
- Non-volatile EPROM memory.
- 100 programmable codes
in 4, 5 or 6 digits.
- 1 relay output N/O contact
6A @ 250V
- 2 relay outputs N/O and N/C
contact 6A @ 250V
- Master code programmable
in 4, 5 or 6 digits
- Warning buzzer.
- 1 request-to-exit input
- P2 jumper: Reset to default master
code and delete all user codes
- P3 jumper: User code modification
by user active
Default values:
- No code.
- Illumination time: 10 seconds.
- Relay release time: 1 second.
- Code length: 5-digits.
- Master Code: 1 2 3 4 5.
- Programming security-lag: 120s.
A. Resetting the memory
1. Enter the master code twice.
- For the first use, the factory
master code is: 1 2 3 4 5.
- Red LED lights on to confirm
entry in programming mode.
2. Then press
6.
- Green LED lights on for 1 second.
- Press
and # to confirm the resetting.
- Green LED lights on. Wait for the lighting to go off.
- The master code is 1 2 3 4 5 again
and all the codes have been erased.
The keypad is reinitialised. Red led lights on,
then lights off.
- The keypad is no longer in the programming
mode and the default values have been restored.
1. Turn off the power supply.
Short the P2 2-pins.
- Sub master code for user code
modification User Group 1: *
and #
- Sub master code for user code
modification User Group 2: 1 and 3
- Sub master code for user code
modification User Group 3: 4 and 6
- Red LED light on when keypad
is powered.
Audible signal correspondence:
- 1 short beep: Keypad powered.
- 1 long beep: Programming
validated and relay activated.
- 2 short beeps: Enter or Exit
from programming.
- 4 short beeps: data computing
error.
Digits used and opening codes:
- All the keypad keys can be used
to program a code.
- The master code and the User
codes can be of 4 or 5 or 6 digit
in length.
- The master code CAN NOT be used
as a user code.
- Codes 0 0 0 0 0 0, 0 0 0 0 0
and 0 0 0 0 can only be used
to delete a user code. To delete
a User Code enter the user number
OR
(location number) then enter
0 0 0 0 if the code length
is in 4-digit format, enter 0 0 0 0 0
if the code length is in 5-digit format.
Control by push button:
- The connection of push button P1
is intended for controlling relay 1.
(the mode and the time-lag
can be programmed).
- H1 input can be used with a timer
to allow free access by pressing
on the O digit key. If the timer
contact is open then the free
access is deactivated. If the timer
is closed then the free access
is activated.
Consumption
(without the control elements)
With the 2 relays controlled:
- In 12 V ac: 20 mA
in stand-by, 100 mA max
with 3 relays activated
- In 24 V ac: 10 mA in stand-by,
50 mA max with 3 relays activated
2. Turn the power supply on again.
- Green LED lights on.
Wait a few seconds, a beep is emitted.
- Green LED lights off. Remove the jumper at P2.
3. The master code is 1 2 3 4 5 again
and all the codes have been erased.
The default values have been restored.
B. Setting code length
1. Enter the master code twice.
- For the first use, the factory master code is:
1 2 3 4 5.
2. Press
4 to input the number of digits
in the codes.
- Green LED lights on for 1 second.
- Enter 4, 5 or 6 for number of digits.
- The green LED lights on for 1 second
to confirm the new code length.
EN
cdvi.com
15