Installation; Dimensions & Specifications - Garland Master Serie Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

INSTALLATION

Dimensions & Specifications
Single-Deck
Models
Standard Depth
29 (736)
Deep Depth
29 (736)
Double-Deck
Models
Standard Depth
29 (736)
Deep Depth
29 (736)
* Height with legs or with standard casters. Height with low profile casters (double deck) is 68-1/2" (1740mm).
Models
Single Deck
Double Deck
3/4" N.PT.
GAS INLET
7-3/4"
[197mm]
3/4"
[19mm]
FLUE: 2-3/8" x 5"
[60mm x 127mm]
D
(includes
fan motor)
17-3/4"
[451mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
H
25-3/8"
[645mm]
Gas Input ratings shown here are for installations up to 2,000-ft. (610m) above sea level. Specify altitudes over 2,000 ft.
Commercial cooking equipment requires an adequate ventilation system. For additional information, refer to the National Fire
Protection Association's standard NFPA96, "Vapor Removal from Cooking Equipment." (NOTE: For North America only)
Please specify gas type when ordering.
6
Int. Dimensions :In (mm)
W
H
D
24 (610)
24 (610)
24 (610)
28 (711)
Int. Dimensions: In (mm)
W
H
D
24 (610)
24 (610)
24 (610)
28 (711)
Input Ratings, Nat & Pro
BTU/hr
kW Equiv.
60,000
17. 6
120,000
35.2
2"
[51mm]
38-1/4"
[972mm]
11-1/2"
[292mm]
TOP VIEW
38"
[965mm]
3/4" REAR
GAS INLET
54-9/16"
[1386mm]
34"
[864mm]
SINGLE DECK
FR ONT VIEW
Ext. Dimensions: In (mm)
W
H *
38 (965)
57-1/2 (1461)
38 (965)
57-1/2 (1461)
Ext. Dimensions: In (mm)
W
H *
38 (965)
70-1/2 (1791)
38 (965)
70-1/2 (1791)
Gas Inlet
(1 )@ 3/4" NPT
(1 )@1" NPT
1-1/4"
[32mm]
32-1/8"
[816mm]
H
32-1/8"
[816mm]
6-1/4"
[159mm]
Operating Pressure:
Natural: 4" WC (10 mbar)
Propane: 10" WC (25 mbar)
Max 13.8" WC @ 70°F (21°C)
NOTE: Data applies only to
North America
Notes:
1. Standard electrical specifi cations include motor requirements.
2. (120V units) 115V 3/4 HP, 2-speed motor; 1140 and 1725 rpm 60Hz
3. (240V units) 200-240V, 3/4 HP, 2-speed motor; 1140 and 1725 rpm, 60Hz
4. A 6 ft. line cord is provided for each 120V deck with a (NEMA #5-15P) plug.
5. Garland recommends a separate 15 AMP circuit for each 120V unit.
Ship Wt
D
Lbs/kg
41-1/4(1048)
515/230
44-1/2(1130)
545/245
Ship Wt.
D
2@Lbs/kg
41-1/4(1048)
1030/465
44-1/2(1130)
1090/490
Electrical Specifications
120V/1Ph.
240V/1Ph.
(1)@9.8A
(1)@ 5.2A
(2)@9.8A
(2)@ 5.2A
32-1/8"
[816mm]
14-3/4"
[375mm]
DOUBLE DECK
FR ONT VIEW
Part Number 1955200 rev 7 4/15
Ship Dim.
Cubic Ft.
64
64
Ship Dim.
Cubic Ft.
128
128
1" REAR
GAS INLET
32-1/8"
[816mm]
35-7/16"
[900mm]