Water Storage Tank Specifications - Sime NATURAL S 160 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WATER STORAGE TANK SPECIFICATIONS

12
10
6
11
9
8
5. Cathode protection
by electrolytic reactions.
6. Large round flange rubber protected:
replacement of anode and immediate access to the electrical components.
7. Complete sealing
it against electrolysis and corrosion, specially made to withstand the generally accepted specifications with regard
to the heat resistance.
8. Heating element
rated according to the country of destination local regulations. (Optional, for the use of electricity
as an auxiliary power source). All electrical components carry a CE marking according to EN 60335-1 and
EN60335-2-21 standards.
9. Automatically regulated thermostat
CE marking according to EN 60335-1 and EN60335-2-21 standards.
10. Protective cover:
environmental conditions.
Gland: for sealing the passage of the heating element's connection cable.
11. Cold water inlet:
pressure (¾" for 250lt and above).
12. Hot water outlet:
13. Jacket inlet:
¾" BSP male threaded pipe end.
14. Jacket outlet:
Closed loop circuit filling point: ¾" BSP male threaded pipe end.
15. Safety valve connection location 1,5 bar (320 lt) or 2,5 bar (160 - 200 lt) :
16. Heat exchanger (optional)
systems during the winter.
8
SIME NATURAL S (vers. LP)
All manuals and user guides at all-guides.com
7
1
2
3
4
5
by magnesium anodes for effective protection against corrosion and mineral deposits caused
innovative, smart design for the quick cleaning of minerals, fast
of EPDM, non toxic material, which does not permit water to contact the flange, thus protecting
with bipolar protection and auxiliary fuse. All electrical components carry a
designed to ensure the proper ventilation of the electrical section and its protection from the
½" BSP male threaded pipe end for water stratification and 8 bar safety valve for releasing
½" BSP male threaded pipe end (¾" for 250lt and above).
with ¾" BSP male threaded ends for use of the heating produced by central heating
1. Cylinder:
with a double internal layer of enamel,
baked at 860°C according to DIN 4753.
The enameling is done in our own high tech
15
industrial facilities. The water storage tanks
are checked individually upon exit from the
enameling unit, assuring the top quality of the
enamel.
2. Surrounding heat exchanger (Jacket):
rolled steel, 1.8 mm thickness for the operation
of the closed loop, which is compulsory at low
temperatures and also in areas with water with
high mineral content. It is specially designed
so as to absorb the heat transfer medium
pressure.
16
14
3. Thermal insulation:
expanded polyurethane ensures minimum heat
loss, maintaining the hot water temperature.
4. External housing:
3 mm thickness cold rolled steel
ecological, high-density,
naval aluminium alloy.
½" BSP male threaded pipe end
cold

Publicité

Chapitres

Table des Matières
loading

Table des Matières