THE SOLAR WATER STORAGE TANK DOES NOT SUPPLY HOT WATER WHEN USING
THE ELECTRICAL HEATING ELEMENT
The following tasks must be carried out only by a qualified electrician.
1.
Shut down the electrical supply and open the electrical
components' cover.
2.
Check the cable connection between the thermostat
and the heating element.
3.
Check the temperature at which the thermostat is set,
so that it is not lower than that needed for consumption.
4.
Check the heating element.
5.
Check the central electrical connection.

SERVICE - MAINTENANCE

Your solar water heater should be serviced every two years by an authorized representative or a company technician.
These periodic checks are necessary for the solar water heater's warranty to apply. The inspection concerns the
whole system and more specifically:
1.
Flange
2.
Safety valve
3.
Heating element - thermostat
4.
Connection fittings
5.
Piping
6.
Insulation - seals
It is recommended that the water storage tank
is cleaned of mineral deposits and sludge every
five years.
Especially for the replacement of the anode bar follow these steps:
1.
Shut down the electrical supply.
2.
Empty the water from the water storage tank.
3.
Remove the electrical component's cover.
4.
Disconnect the three electrical wires.
5.
Remove the electrical heating element by removing
the M8 screws.
6.
Remove the old magnesium bar from the heating
element's flange.
7.
Screw in the new magnesium.
8.
Replace the heating element with the rubber seal.
For solar water storage tanks with a heating coil a periodic check by a qualified technician is recommended.
30
SIME NATURAL S (vers. LP)
All manuals and user guides at all-guides.com
6.
7.
7.
Transparent cover (solar glass)
8.
Supporting system
9.
Replacement of anode and
checking the closed loop's liquid.
9.
10.
11.
12.
13.
14.
Switch on the electrical current and measure the
voltage at the heating element's terminals.
Check the thermostat's thermoelectric fuse, which
must be pressed in. If it is not, rotate the thermostat's
regulator until the button of the thermoelectric fuse
appears. Press this. Once it has been reset, the
thermostat can operate once again.
Open the water supply and a hot water tap until the
water storage tank fills up.
Check for water leaks.
Reconnect the electrical components at their
designated positions.
Check that the thermostat is securely clipped to the
heating element.
Replace the electrical component's cover.
Reconnect the electrical supply.