Installation
3
Install the extension receiver in the rack
Use rack-installation screws (x4) to securely fix the extension receiver.
● Rack-installation torque: 2.0 N•m to 2.4 N•m {20.5 kgf•cm to 24.5 kgf•cm}
Rack-installation screws
x4 (locally procured)
● Make sure that the temperature inside the rack does not exceed +45 °C
(113 °F).
Important
● Do not place the extension receiver near devices which diffuse large
amounts of heat (eg: power amplifiers).
If it is absolutely necessary to do so, leave at least 1 U (44 mm (1-3/4
inches)) of free space between the extension receiver and the heat-
diffusing device.
● When installing heat-sensitive devices in the same rack as the extension
receiver, place them lower than the extension receiver itself.
● Install the rack at well-ventilated location. Ventilate the rack so that
accumulated heat does not bring the internal temperature over +45 °C
(113 °F).