Télécharger Imprimer la page

Kozy Heat Fireplaces NCK-SL60-D Guide Rapide page 5

Publicité

Les langues disponibles

Les langues disponibles

F. Test Inlet Pressure
IMPORTANT: For a proper pressure reading, apply the gas supply
pressure tests with all other gas appliances on or at full capacity in the
household.
Step 1: Loosen the inlet (IN) pressure tap screw (counterclockwise) on
the gas valve. See (A) in FIGURE 7.
Step 2: Attach a manometer to the inlet pressure tap with a
ID hose.
Step 3: Light the pilot and burner. Verify manometer reading is
between the recommended minimum and maximum pressure
settings. See TABLE 3.
Step 4: Turn off pilot and burner.
Step 5: Disconnect hose and tighten the inlet pressure tap screw
(clockwise). The screw should be snug; do not over tighten.
Step 6: Relight the pilot and burner.
Step 7: Reattach the manometer to the inlet pressure tap to verify tap
is completely sealed. Manometer should read no pressure.
Table 3, Inlet Gas Supply Pressures
Fuel
Minimum
Natural Gas
5" WC (1.25 kPa)
G. Test Manifold Pressures
Step 1: Loosen
the
manifold
(counterclockwise) on the gas valve. See (B) in FIGURE 7.
Step 2: Attach a manometer to the outlet pressure tap with a
ID hose.
Step 3: Light the pilot and burner. Verify manometer reading is
between the recommended low and high pressure settings.
See TABLE 4.
Step 4: Turn off pilot and burner.
Step 5: Disconnect hose and tighten the outlet pressure tap screw
(clockwise). The screw should be snug; do not over tighten.
Step 6: Relight the pilot and burner.
Step 7: Reattach the manometer to the outlet pressure tap to verify tap
is completely sealed. Manometer should read no pressure.
Table 4, Manifold Gas Supply Pressures
Fuel
Low
Natural Gas
1.0" WC (0.24 kPa)
FIGURE 6, Pressure Check Taps
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
1/4
" (6mm)
Maximum
10" (2.49 kPa)
(OUT)
pressure
tap
screw
1/4
" (6mm)
High
3.5" WC (0.87 kPa)
H. Verify Operation
Step 1: Light the pilot. Visually check the pilot flame to verify flame
envelops the top of the flame sensor and extends far enough
onto the burner for proper ignition. See FIGURE 8.
Step 2: Turn the appliance off.
Step 3: Affix the gas type sticker on or near the gas valve.
Step 4: Reinstall the glass frame assembly and safety barrier.
Step 5: Light the pilot and burner. Visually check the main burner flame
appearance (FIGURE 9) for proper ignition and operation of
the fireplace. Refer to the installation manual for complete
adjustment procedures.
Step 6: Complete and affix the 'Gas Conversion' labels as close to the
rating plate as possible.
Step 7: Verify the input rating of the converted appliance. See TABLE 5.
Table 5, Input Ratings
Fuel
Minimum Input
Natural Gas
28,000 Btu/h (8.20 kW)
BURNER PORTS
CORRECT PILOT FLAME APPEARANCE
FIGURE 7, Burner Ports Location and Correct Pilot Flame Appearance
Ideal Flame Appearance
Lazy, yellow ames - no adjustment necessary
FIGURE 8, Ideal Burner Flame Appearance
EN
Maximum Input
55,000 Btu/h (16.12 kW)
5
#NCK-SL60-D
R.1

Publicité