- Hands position control : this parameter enables/disables detection of faults in the position of the
hands.
- Shock: this parameter enables/disables detection of shock to the clock (accelerometer measuring
clock movement, 3 levels of sensitivity).
- Open case: this parameter enables/disables detection of the clock being opened.
- Lighting failure: this parameter enables/disables detection of a fault with the clock illumination.
- Low lighting failure: this parameter enables/disables detection of low illumination level.
- Battery backup failure: this parameter enables/disables detection of low battery level.
- Power failure: this parameter enables/disables detection of a power supply fault (mains power
cut).
- Temperature: this parameter enables reporting of high or low temperature threshold breaches
(variable temperature range).
- Periodic Status: this parameter enables periodic sending (configurable interval) of an alarm to
indicate to the SNMP Manager that the clock is still "alive". The alarm consists of the clock's status.
Information : the errors or faults reported are minor and do not in themselves require a
visit by a maintenance technician to correct the fault.
Warning: the errors or faults reported are to warn the user, and require a visit by a
maintenance technician to correct the fault.
Critical: the errors or faults reported are serious and require a prompt visit by a maintenance
technician to correct the fault.
The Save button saves the configuration data entered.
The Send status trap button sends a status trap to all configured SNMP Managers in order to
confirm that monitoring has been correctly configured.