ENGLISH
DECOR-100 Axial Extractor Fans
The DECOR-100 extractor fan range
is manufactured to the high standards
of production and quality as laid down
b
y
h t
e
n i
e t
n r
t a
o i
n
ISO 9001. All components have been
checked and every one of the final
products will have been individually
tested at the end of the manufacturing
process.
On reciept of the product we recommend
that you to check the following :
1- That it is the correct size.
2- That it is the correct model.
- 3
T
h
t a
h t
e
d
e
a t
s l i
are those you require: voltage,
frequency ...
The installation must be carried out in
accordance with the electrical standards
in force in your country.
Installation
IMPORTANT: Before installing and
wiring the unit, ensure that the main
supply is disconnected.
Fig. 1:
1- Protection grille
2- Fixing screw
3- Connection terminals
4- Outlet with backdraught shutter
5- Cable entry
The DECOR-100 is suitable for wall
or ceiling mounting and can either
discharge directly to the outside or via
a
n
n i
d
v i
d i
u
l a
r o
c
e
(see Fig. 2).
The unit can be mounted on the wall or
ceiling using the 4 rubber blocks and the
screws provided.
M
a
k
e
a
h
o
e l
n i
h t
105 mm dia.
If the unit is to be installed with individual
ducting, use a standard 100 mm dia. duct.
Undo the two grille fixing screws (1).
Ensure that there are no obstructions to the
airflow and that the impeller turns freely.
l a
Q
u
i l a
y t
S
a t
n
d
a
o
n
h t
e
r
t a
n i
g
a l
b
n
r t
l a
d
u
t c
n i
g
s
s y
e t
e
w
l l a
r o
c
i e
n i l
g
Fix the extractor to the wall in such a way
that it is not distorted in order to avoid
noise generation or problems with the
rotation of the impeller. Make sure that
the backdraught shutter opens freely
and has not being damaged in transit.
d r
Introduce the mains cable through the
cable entry (5) and fix it to the wall so
that the fixing screw (2) is above.
Connect the electrical wiring as set out
below and then mount the protection
grille (1) and tighten the screw (2).
Electrical connection
The DECOR-100 is an extractor desig-
ned for a single phase supply, with
l e
voltage and frequency as indicated on
the rating plate of the unit. The units
are manufactured with double electrical
insulation (Class II) and therefore they do
not need an earth connection.
The electrical installation must include
a double pole switch with a contact
clearance of at least 3 mm.
The electrical cable must enter the
DECOR-100 through the cable entry (5).
Once the cable has been introduced
proceed using the electrical wiring
diagram applicable to the selected
model.
DECOR-100 C and CZ
For these models use the following
diagrams:
Fig.3: Switching the extractor through
the light switch.
Fig.4: To switch the fan through an
independent switch.
m
DECOR-100 CMZ
Models fitted with on/off pullcord switch
use the following wiring diagrams:
Fig.3: Fan operating through a light switch.
Fig.4: Fan operating through an independent
switch or sensor.
f o
DECOR-100 CR and CRZ
These models are provided with an
adjustable timer. The timer allows the fan
to continue to operate for the selected
period after the switch has been turned
off (fig.5).