Technical Characteristics - Gima SUPER VEGA BATTERY Mode D'emploi

Aspirateur
Masquer les pouces Voir aussi pour SUPER VEGA BATTERY:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

All manuals and user guides at all-guides.com
The manufactured cannot be held liable for accidental or indirect damages should the device be modified,
repaired without authorization or should any of its component be damaged due to accident or misuse.
Any minimal modification / repair on the device voids the warranty and does not guarantee the compliance with
the technical requirements provided by the MDD 93/42/EEC (and subsequent changes) and its normatives.
INSTRUCTIONS FOR THE CORRECT DISPOSAL OF THE PRODUCT FOR THE PURPOSE AND EFFECT OF
EUROPEAN COMUNITY DIRECTIVE 2002/96/EC::
At the end of its useful life the product must not be disposed of with domestic waste.
It may be delivered to the relevant separate waste collection centres prepared by municipal administrations, or at
retailers that supply this service. Disposing of the product separately prevents possible negative consequences for
the environment and for health, deriving from inadequate disposal.
It also allows the recovery of materials of witch it's made up in order to obtain an important saving of energy and
resources. In order to point out the obligation to dispose of the electromedical appliances separately, the product
has the sign of the crossed mobile waste container applied to it.
Model
Typology (MDD 93/42/EEC)
UNI EN ISO 10079-1 Classification
Power Feeding
Current Consumption
Maximum Suction Pressure (without jar)
Minimum Suction Pressure (without jar)
Maximum Suction Flow (without jar)
Weight
Insulation Class (when used with the AC/DC adapter mod.
UE60-140429SPA3)
Insulation Class (when used with an Internal battery)
Insulation Class (when used with a car cigarette lighter cable)
Size
Battery Holding Time
Battery Time Charge
Accurancy of Vacuum Indicator
Working Condition
Conservation condition and Transport

TECHNICAL CHARACTERISTICS

14V
FUHUA (input: 100-240V~ - 50/60Hz - 100VA) or Internally
powered equipment (Pb Battery 12V
Room Temperature:
Room humidity percentage
Altitude:
Room Temperature:
Room humidity Percentage:
13
SUPER VEGA BATTERY
Class IIa Medical device
HIGH VACUUM / HIGH FLOW
4A with AC/DC adapter mod. UE60-140429SPA3 of
lighter adapter (12V
4.0A
-80kPa (- 0.80 bar)
Less -40kPa (-0.40 bar)
36 l /min
4.39 Kg
Class I
Internally Powered Equipment
Class II
357 x 193 x 215 mm
60 minutes
120 ÷ 150 minutes
± 5%
5 ÷ 35° C
30 ÷ 75% RH
0 ÷ 2000m s.l.m
- 40 ÷ 70° C
10 ÷ 100% RH
4A) or with cigarette
4A)