Translation of the original instructions
- Protection against the rain inclined at 60° towards the vertical.
These devices can be used outside in accordance with the IP23 protection index.
• The power cables, extensions and welding cables must be fully uncoiled to prevent overheating.
The manufacturer does not incur any responsability regarding damages to both objects and persons that result from an incorrect
and/or dangerous use of the machine.
MAINTENANCE / RECOMMENDATIONS
• Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.
• Ensure the machine is unplugged from the mains, and wait for two minutes before carrying out maintenance work. DANGER
High Voltage and Currents inside the machine.
• Remove the casing 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical connections checked by a qualified
person, with an insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, its after sales
service or an equally qualified person.
• Ensure the ventilation holes of the device are not blocked to allow adequate air circulation.
• Do not use this equipment to thaw pipes, to charge batteries, or to start any engine.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorized by the manufacturer should perform the installation of the cutting equipment. During set up, the operator must
ensure that the machine is unplugged. It is recommended to use the welding cables supplied with the unit in order to obtain the optimum settings
of the product.
HARDWARE DESCRIPTION (FIG-1)
The IMS 220 FV CEL is a single phase inverter welder which, depending on its equipment, can do :
- Electrode welding (MMA)
- Tungsten electrode welding (TIG)
The TIG process requires gas shielding (Argon).
The MMA process can weld any type of electrode : rutile, basic, cellulosic, stainless and brass.
1-
Man to Machine Interface
2-
+ polarity plug
3-
- polarity plug
POWER SUPPLY
• This equipment is supplied with a 16 A CEE7 / 7 plug and must be connected to a three-wire 230V (50-60 Hz) single-phase electrical installation
with the earthed neutral. The 200E FV CEL integrates a « Flexible Voltage » system. It has to be plugged on a power supply variable between 110V
and 240V (50 – 60 Hz) WITH earth. The absorbed effective current (I1eff) is shown on the machine, for maximal using conditions. Check that the
power supply and its protection (fuse and/or circuit-breaker) is compatible with the necessary current during use. For intensive use at 230Vrms and
110Vrms, disconnect the original plug and replace it with a 32A plug protected by a 32A circuit breaker. The welder must be installed so that the main
plug is accessible.
• The power is switched on by rotating the On/Off switch to position I, conversely the power is switched off by rotating it to position O. Warning!
Never disconnect the power supply while the machine is charging.
The device turns into protection mode if the supply voltage is over 265V for the single-phase products (the sсreen displays
Normal operation will resume when the voltage has returned to its nominal range.
CONNECTION ON A GENERATOR
The machine can work with generators as long as the auxiliary power matches these requirements :
- The voltage must be AC, always set as specified, and the peak voltage below 400V
- The frequency must be between 50 and 60 Hz.
It is imperative to check these requirements as several generators generate high voltage peaks that can damage these machines.
USE WITH EXTENSION CABLES
All extension cables must have an adequate size and section, relative to the machine's voltage .
Use an extension that complies with national safety regulations.
IMS 220 FV CEL
IMS 220 FV CEL
4-
On/off switch
5-
Power supply cable
Input voltage
Wire section of extension cord (<45m)
230 V - 1~
110 V - 1~
2.5 mm²
2.5 mm²
EN
).