PLEASE NOTE: If
not used, the normally
closed inputs (STOP,
PHOTO, EDGE) must be
jumpered with the
commands common line
COM (-)
L1
Antenna
L2
Antenna shield
Opening command for a standard connection device
L3
with switch normally open.
Pedestrian opening command for a standard
L4
connection device with switch normally open.
L5
STOP command. N.C. switch
L6
Photocell. N.C. switch
L7
Edge. Switch N.C. or resistive rubber edge
L8
Commands common (-) line
24 VAC power output for photocells and other
L9 - L10
accessories
L10 - L11 Power supply for functional test TX photocell
ADJUSTMENT OF THE POWER AND
OPERATIONAL TIMES
The power and operating times may be adjusted by means of 4
trimmers located on the control unit:
POWER:
motor power.
WORK:
motor operating time (5 - 120 seconds).
PLEASE NOTE: it is recommended that operating times be
set with the slow down function disabled (DIP 5 OFF).
PAUSE:
pause time before automatic re-closure
(5 - 120 seconds).
DELAY:
time delay between the two gate leaves
(0 - 60 seconds).

CONTROL UNIT INDICATORS (LEDS)

The highlighted boxes indicate the state of the LEDs when the
gate is resting.
ELECTRICAL CONNECTION TABLE
J1
K9 - K10 230V - 40W / 120V - 40W blinker
LED
START
IN2
STOP
PHOTO
EDGE
mains
overload
8
K1 - K2
Courtesy light timer activation switch
K3
Motor 1 open
K4
Motor 1 common
K5
Motor 1 close
K6
Motor 2 open
K7
Motor 2 common
K8
Motor 2 closed
N
230V / 120V power supply - neutral
L
230V / 120V power supply - phase
J1
NOT USED
ON
START input closed
START P. input closed
STOP input closed
PHOTO input closed
EDGE input closed (edge
not pressed)
Resistive rubber edge
EDGE input closed (edge
pressed)
Edge NO pressed: 8K2
between EDGE input
and common (-)
Control unit powered-up Control unit NOT powered-up
Accessory power supply
overload
OFF
START input open
START P. input open
STOP input open
PHOTO input open
Standard edge
EDGE input open (edge
pressed)
EDGE input open
(fault)
Accessory power supply within
normal operational limits