ATTENTION: If the STOP input is not used must be jumpered with the commands common line COM (-)
A1
Antenna shield
A2
Antenna
Opening control for the connection of control
P1
devices with N.O. contact
Opening controls for pedestrian access for the
P2
connection of control devices with N.O. contact
P3
Stop command. N.C. contact
P4
Common (-)
P5
Photocells type 1. N.C. contact
P6
Photocells type 2. N.C. contact
P7
Safety ribbons type 1 (fixed). N.C. contact
P8
Safety ribbons type 2 (mobile). N.C. contact
P9
Common (-)
P10
Opening end of stroke. N.C. contact
P11
Closing end of stroke. N.C. contact
Power output 24 VAC for photocells and other
P12
accessories
P13
Photocell TX power supply for functional test
P14
Common (-)

ELECTRIC CONNECTIONS TABLE

W1 - W2 -
W3
W4 - W5
B1 - B2
1L1 - 3L2 -
5L3
F1
F2 - F4
F3
ADI
MAINS
OVERLOAD
FCC
FCA
OP
PA
CL
36
Motor (see paragraph POWER SUPPLY AND
MOTORS)
Clamps to connect the motor's earth system to the
plant's earth system
Flashing light 230VAC 40W
Power supply (see paragraph POWER SUPPLY AND
MOTORS)
400mA
2A
2A (500V)
Optional modules connector
It shows that the control unit is power supplied
It shows that there is an overload on accessories
power supply
It shows the opening end of stroke activation
It shows the closing end of stroke activation
Opening in progress
Pause (gate opened)
Closing in progress