What not to do!
Do not touch the head, the cylinders, the cooling fins or the feed line, because during
operation they reach very high temperatures and remain hot even for some time after
the device has been stopped.
Never place flammable materials on or near the compressor.
Never direct the compressed air stream toward people or animals.
Do not run the compressor without an air filter.
Do not use the device in a potentially explosive environment.
The air flow to cool the compressor unit must not be impeded. Therefore, position at
least 50 cm away to obstacles.
2
Technical Data
Compressor:
Pipe connection ................................ R 1" GK-coupling
Max. Flow rate .................................. 5 m³ / h
Water pressure ................................. max. 7 bar
Water temperature ............................ 30 °C
Protection ......................................... IP 22
Protection class ................................ I
Suction ............................................. 200 l/min.
Working pressure .............................. Max. 8 bar
Tank capacity ................................... 9,5 litre
Motor output ..................................... 1,5 kW
Main supply ...................................... ~230 V, 50 Hz
Intermittent ........................................ S3 15%
Noise pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear ear protection!
Measurements found in compliance with EN 61029-1:2010.
Micro-filter:
Oil retention rate ............................... 99,9%
Particle –backing rate ....................... 0,3 µm
New filter element in Deshydrator ..... Every 6 months
3
Scope of delivery
–
ROPULS cleaning compressor including GK joint 1"
–
Accessories: connection consisting of a reinforced hose and 1" joint
–
Operating manual
–
Test report
–
Optional accessories: ROCLEAN Injector
1. Control panel with Program keys
2. Coupling for connecting hoses
3. Quick coupling for Compressed air connection
4. Pressure Indicator Compressed air tank
16
) .................. 77 dB (A) | K
pA
) .................... 88 dB (A) | K
WA
Suction, air, filter element and compressor cleaning every
month.
ENGLISH
3 dB (A)
pA
3 dB (A)
WA
(A)