INSTALLATION AND MAINTENANCE
INSTALLATION OF SOLENOID PILOT VALVE(S)
Install solenoid valves in the position determined by the rear polarising stud(s)
SHUT-OFF VALVE
+
AUTOMATIC SOFT-START DEVICE
MODULAIR 107
Size 22 CNOMO pilot
Size 30 CNOMO pilot
series 302
series 189
2
1
2
3
3
4
882 63 001
MODULAIR 112
189
190
2
3
1
1
Pilot(s) supplied separately
Connector size 15 rotatable by 90° increments (pilot 302)
2
Connector size 22 rotatable by 180° increments (pilot 189)
ISO 4400 connectors rotatable by 90° increments (pilot 190 or 192)
Coil rotatable x 360° (pilot 189 or 302)
3
Coil(s) rotatable by 90° increments (pilot 190 or 192)
Polarising stud(s) for installation of solenoid valve(s)
4
Pressurisation adjustment screw
5
Adjustment locking pin
6
Pilot type 302 is to be mounted on a size 15
series 190
CNOMO version shut-off valve type Modular 107
(with the size 15/30 CNOMO interface, code
2
882 63 001).
Install the adapter as indicated opposite to fit
the two polarising studs (4) side by side, then
install solenoid valve 302.
The mounting direction as shown in the
drawings below must be observed when installing
the pilot valve 189 00 007 (without manual
override) onto these products.
3
4
6
5
SHUT-OFF VALVE
+
SOLENOID/AIR CONTROLLED SOFT-START DEVICE
MODULAIR 112
189
190
2
2
3
1
3
4
6
5
Important: if a pilot is to be installed on the
solenoid/air controlled soft-start
device, the pin (6) must first be
removed (see Fig. 1 overleaf)
13
ADJUSTMENT OF DOWNSTREAM PRESSURE BUILD-UP TIME
GB
GB
In both soft-start device versions, the filling rate, i.e. the pressure build-up in the downstream circuit, is adjusted by means of a
fine-thread screw. Components are supplied with the screw fully in (closed position, zero flow).
Adjustment is as follows:
- Unscrew the screw by 0.5 to 6 turns to obtain the desired filling speed (Fig. 2).
- Perform a test.
- Regulate the setting by adjusting the screw. Before retesting, vent the installation with the shut-off valve.
- When the correct setting is obtained, insert the pin to lock the screw and prevent unauthorised adjustment of regulated
pressure (see Fig. 3). To change the adjustment, it is necessary to remove the upper cover and withdraw the pin (Modulair 112).
Note: With a solenoid/air controlled soft-start device, the adjustment must be made with the electrical pilot installed (see Fig. 2).
To fit the locking pin, it is necessary to vent the installation and remove then reinstall the pilot (see Fig. 3 and 4).
Version with automatic
soft-start device
1
2
3
Fig. 3
4
MODULAIR 112
6
Fig. 2
5
Fig. 3
Version with solenoid/air controlled
soft-start device
2
MODULAIR 107
MODULAIR 112
Fig. 2
1
3
2
Fig. 1
4
1
5
2
Fig. 3
14
3
Fig. 2
6
Fig. 4