• A qualified electrician must install the clamp-
ing connections correctly.
• Use a strain relief clamp on cable.
• Use the correct mains connection cable and
replace the damaged mains cable with the
proper cable type. Speak to your local Serv-
ice Centre.
The appliance must have the electrical installa-
tion which lets you disconnect the appliance
from the mains at all poles with a contact open-
ing width of minimum 3 mm. You must have
correct isolation devices: line protecting cut-
outs, fuses (screw type fuses removed from the
holder), ground leakage trips and contactors.
The manufacturer is not responsible for
any injury to persons and pets or damage
to property caused by failure to obey
these requirements.
Electrical connection
• Ground the appliance according to safety
precautions.
• Make sure that the rated voltage and type of
power on the rating plate agree with the volt-
age and the power of the local power supply.
• The appliance is fitted with a five pole termi-
nal box whose cables are predisposed for
230 V monophase function.
1 2 3 4 5
In case of different voltage, carry out the
connection as shown in connection sche-
matic table on the lower protection.
• Any electrical component must be installed
or replaced by the Service Force Centre
technician or qualified service personnel.
• Always use a correctly installed shockproof
socket.
• Make sure that there is an access to the
mains plug after installation.
www.zanussi.com
All manuals and user guides at all-guides.com
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
• The appliance must not be connected with
an extension cable, an adapter or a multiple
connection (risk of fire). Check that the
ground connection is in conformity with the
standard and regulations force.
• The power cable must be placed in such a
way that it does not touch any hot part.
• Connect the appliance to the mains with a
device that lets to disconnect the appliance
from the mains at all poles with a contact
opening width of minimum 3 mm, eg. auto-
matic line protecting cut-out, earth leakage
trips or fuse.
• None of a parts of the connection cable can
not get a temperature 90°C. The blue neutral
cable must be connected to the terminal
block label with "N". The brown (or black)
phase cable (fitted in the terminal block con-
tact marked with "L") must always be con-
nected to the live phase.
Connection cable
Use only connection cable of type H05V2V2-F
T90 or equivalent type. Make sure that the ca-
ble section is applicable to the voltage and the
working temperature. The yellow/green earth
wire must be approximately 2 cm longer than
the brown (or black) phase wire.
Building In
min. 55 mm
30 mm
10 mm
3 mm
min. 650 mm
560 mm
A
11 mm
11 mm