Télécharger Imprimer la page

Factory Reset - Rechner Sensors KXA-5-1 ET Serie Notice D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

All manuals and user guides at all-guides.com
Technical data KXA-5-1...
Electrical version
Output function
Operating voltage (U
B
Voltage drop max. (U
Permitted residual ripple max.
Operating current (I
)
e
No-load current (I
)
o
Frequency of operating cycles max.
Switching hysteresis
Repeat accuracy
Permitted ambient temperature
LED-display
Protective circuit
Degree of protection IEC 60529
Connection cable
Housing material
EasyTeach-philosophy
t = 0
5s
Adjustment „empty"
10s
15s
>20s
)
)
d
Menu item
Adjustment „full"

Factory reset

Test
4-wire DC
Antivalent (NO + NC)
18...36 V DC
< 2.5 V
25 %
2 x 0...200 mA
Typ. 50 mA
50 Hz
≤ 20 %
≤ 1 %
-25...+55 °C
Green / yellow
Built-in
IP 65
2 m, PUR, 4 x 0.14 mm²
PA
Adjustment ETW:
The EasyTeach menu starts, by activating the
EasyTeach connection (Teach wire / Teach
pin with the supply voltage UB+).The desired
Menu point is selected when breaking the
connection at the defined time.
Adjustment ETM:
Holding the EasyTeach magnet on the
teachspot activates the EasyTeach menu.
The desired menu item is selected by remov-
ing the magnet after the specified time.
EasyTeach
chart: LED green / yellow
Adjustment "empty"
Initializing "empty"
Adjustment "full"
Initializing "full"
Factory reset
Test
19

Publicité

Chapitres

loading