Device Status; Operating Concept - Dräger X-am 3500 Notice D'utilisation

Masquer les pouces Voir aussi pour X-am 3500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 44
measuring function for toxic gases. See the supplementary
documentation for certified gases and measured values (part
no. 90 33 655).
CSA-specific information:
Only the combustible gas part of this instrument has been
tested for measuring accuracy.
Radio approval (X-am 8000 only):
The information for radio approval can be viewed in the menu.
For further information, see the following chapter: "Opening
information", page 33.
Approval-related accessories:
This chapter contains an overview of the key parts covered by
the BVS and PFG certification. Information on other parts can
be found in the spare parts list or can be requested from
Dräger Service. The same ambient conditions that apply for
the gas detector also apply for the accessory. For further
information see: "Gas detector", page 43.
Description
Carrying strap
Calibration adapter CAL 2.0
Pump adapter with dust and
water filter
Pump adapter "Nona" with
dust and water filter
Induction charger
The data logger is not part of the technical suitability test.
3.5
Label
The energy supply label has a mark for a service label. Here,
a maximum of one service label and one year-point label may
be attached one on top of the other. Further labels, conductive
labels or labels with conductive material or parts can have a
negative effect on inductive charging.
The rating plate on the gas detector must not be
concealed.
3.6
Sensor slots X-am 3500
Term
Sensor slot
HPP 1 (High Power Port)
HPP 2 (High Power Port)
EC 1-3 (Electro Chemical)
4
Operation
4.1

Operating concept

Navigation is done with the 3 multifeature buttons and the
dynamic navigation bar (see Graphic E on the fold-out page).
The navigation bar changes dynamically depending on the
available interactions.
Instructions for use
|
X-am
Part number
8326823
3720224
8326820
3720225
8325825
Configuration
not assigned
CatEx sensor
EC sensors
®
3500
4.2
Symbol explanations
4.2.1 feature buttons
Symbol
Explanation
Confirm action/dialog / return to menu
Confirm all
Scroll up / through display
Scroll down / through display
Cancel action
Display quick menu
Display measuring channels individually
Display all measuring channels
Increase value
Decrease value
Repeat feature
Display menu
4.2.2 Displays
Symbol
Explanation
Horn and vibration for gas alarm deacti-
vated
4.2.3 Application
Symbol
Explanation
Measuring
Fresh air calibration
Bump test or calibration

4.2.4 Device status

Symbol
Explanation
Overview of the bump test intervals acti-
vated (additional information for the D-Light
feature).
There are no gas alarms or errors.
Monitoring of the calibration intervals acti-
vated, D-Light function deactivated (addi-
tional information for the D-Light function).
There are no gas alarms or errors.
Alarm message
Warning message
The gas detector can be operated nor-
mally. If the warning message is still dis-
played after operation, the gas detector
requires maintenance. Menu Messages
displays details.
|
en
Operation
29