OPERATING INSTRUCTIONS

GENERAL OPERATION

Make sure the charger is disconnected from AC power before connecting the batteries to the output cords.
After the AC cord on the charger is plugged in and a battery is connected to the output cable correctly, the 25% charging LED will turn
on. After 2 seconds, the charger will begin charging the battery. The YELLOW LEDs will indicate how far the charger is in the charging
process. Once the 100% GREEN LED is blinking, the charger is holding the float voltage. The charger will hold the batteries float voltage
for 24 hours. After 24 hours, the charger output will turn off and the 100% blinking GREEN LED will switch to steady GREEN. For
specifics on Lithium Batteries, please see the "LED Patterns" section of this Manual.
Lithium batteries can shut themselves off after extensive use under certain conditions. This protective condition is referred to as Standby
Mode. Refer to your Lithium Battery Owner's Manual to learn more about conditions that could activate Standby Mode. Your Minn Kota
charger has an Auto Start system set up to automatically restart the battery a set number of times to take the Lithium Battery out of
Standby Mode so that is can be charged.
NOTICE:
If a
RED LED is blinking, reference the ERROR CONDITIONS in the "Troubleshooting" section of this manual to
determine the reason and take the necessary corrective action to remedy the situation. If you are unable to remedy the situation
and need help, call the Minn Kota Service Department at 1.800.227.6433 and a technical support representative will be happy
to assist you.
We recommend that you not recharge your battery, (or batteries), with the watercraft or motor lower unit in the water during electrical storms.
Severe damage to the motor or charging system may occur if lightning strikes nearby or if storm- related high voltage conditions exist.
CAUTION
If using a generator to power the charger, it must have a clean
output and be safe for use on electrical equipment. Generators
with a sine wave output can be used to power this charger. See
"Power Requirements" table for details.
WARNING
To reduce risk of electric shock, do not perform any servicing
other than those contained in the operating instructions.

INLINE FUSE

Each output cord has inline fuses on the RED and BLACK leads located near the ring terminals. These fuses serve as protection from
surges and short circuits caused by a damaged charger output cable. If a fuse blows, replace it with a 30 amp ATC 32V automotive fuse.
Improper battery connections will normally not cause a fuse to blow since this is handled by the internal circuitry of the charger.
18 | minnkotamotors.com
WARNING
CAUTION
MK 106PCL
MK 212PCL
MK 318PCL
MK 110PCL
MK 220PCL
MK 330PCL
MK 440PCL
MK 550PCL
Power Requirements
Model
Input Power (120VAC, 60Hz)
©2021 Johnson Outdoors Marine Electronics, Inc.
90W
180W
270W
150W
300W
450W
600W
750W