Confi Gure The Control Panel; Confi Gure The Aqualink Rs Control System; Install The Remote Tstat - Jandy JRT Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy
®
JRT Series Heat Pumps
Figure 10a.
Remote Pool-Off-Spa Connection
(3-Wire Connection)
5.
Restore power to the heat pump and the pool/spa
control system.

Confi gure the Control Panel

1.
Make sure the control is in the OFF mode.
2.
To enter the Service Setup mode, press and hold
the MENU, POOL, and SPA buttons for 5
seconds.
NOTE The display will revert back to OFF after one
minute since the last key press.
3.
Press the Up or Down button to display
REMOTE. Press the MENU button. The
SELECT REMOTE OFF (default remote)
appears, use the Up or Down button to scroll
through the Remote options. When you reach HI-
LO-COM, press the MENU button to select the
remote. Press POOL or SPA to exit the Service
Setup mode.
Two-Wire Connection to an AquaLink
TSTAT
A 2-wire remote will only control one function; heating
or cooling. It cannot control both functions with the
remote control.
Confi gure the AquaLink RS Control
System
1.
Turn off the power to both the pool/spa control
system and the heat pump unit.
2.
Connect two (2) wires to the AquaLink RS green
10-pin terminals 1 and 2.
3.
Put DIP S2-1 (pin #1 of the 4 position DIP switch)
into the ON position (see Figure 11).
|
Installation and Operation Manual
RS or
®
ENGLISH
Figure 10b.
AquaLink RS or Remote TSTAT
Connection (2-Wire Connection)

Install the Remote TSTAT

1.
Turn off the power to both the pool/spa control
system and the heat pump unit.
2.
Remove the screws that attach the service/access
panel to the heat pump unit and the cover to the
junction box (See Figure 9).
3.
Run the wires from the pool/spa control system
into the conduit connection labeled "low voltage
connection", located on the lower right hand side
of the heat pump (See Figure 9).
4.
Connect the wiring from the pool/spa control
system to the heat pump remote control terminal
(See Figure 10b).
5.
Restore power to the heat pump and the pool/spa
control system.
Confi gure the Control Panel
1.
Make sure the control is in the OFF mode.
2.
To enter the Service Setup mode, press and hold
the MENU, POOL, and SPA buttons for 5
seconds.
NOTE The display will revert back to OFF after one
minute since the last key press.
3.
Press the Up or Down button to display
REMOTE. The SELECT REMOTE OFF
(default remote) appears, use the Up or Down
button to scroll through the Remote options. When
you reach REMOTE TSTAT, press the MENU
button to select the remote. Press POOL or SPA
to exit the Service Setup mode.
4.
Press SPA. For heating, adjust the setpoint to the
maximum setting. For chilling, adjust the setpoint
to the minimum setting.