Bonding; Optional Remote Controls; Configure The Control Panel - Jandy JE1500T Manuel D'installation Et De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

|
Jandy
®
JE Heat Pumps
SERVICE ACCESS
PANEL (5 SCREWS)
Figure 10. Jandy JE Heat Pump Front View
4.3

Bonding

CAUTION
This heater must be connected to a bonding
grid with a solid copper wire not smaller in
diameter than 8 AWG (In Canada, it shall be no
smaller than 6 AWG.)
The National Electrical Code
codes require that all metallic components of a pool
structure, including reinforcing steel, metal fittings,
and above ground equipment be bonded together with
a solid copper conductor not smaller than 8 AWG. The
heat pump, along with pumps and other pool equipment
must be connected to this bonding grid. A bonding lug
is provided on the right hand side of the heat pump to
ensure this requirement is met.
4.4

Optional Remote Controls

Electrical wiring must be in accordance with all
applicable national and local codes and ordinances.
Connection to a Remote Pool-Off-Spa Selector
(3-Wire Connection)
Install the Remote Pool-Off-Spa Selector
1.
Turn off the power to both the pool/spa control
system and the heat pump unit.
Installation and Operation Manual
and most other U.S.
®
ENGLISH
CONNECTOR FOR
HIGH VOLTAGE WIRES
CONNECTOR FOR
LOW VOLTAGE WIRES
2.
Remove the screws that attach the service/access
panel to the heat pump unit and the cover to the
junction box (see Figure 10).
3.
Run the wires from the pool/spa control system
into the conduit connection labeled "Low Voltage
Connection", located on the lower right hand side
of the heat pump (see Figure 10).
4.
Connect the wiring from the pool/spa control
system to the heat pump remote control terminal
(see Figure 11a).
5.
Restore power to the heat pump and the pool/spa
control system.

Configure the Control Panel

1.
Make sure the control is in the OFF mode.
2.
To enter the Service Setup mode, press and hold
the MENU, POOL, and SPA buttons for 5
seconds.
NOTE The display will revert back to OFF after one
minute since the last key press.
3.
Press the Up or Down button to display
REMOTE. Press the MENU button. The
SELECT REMOTE OFF (default remote)
appears, use the Up or Down button to scroll
through the Remote options. When you reach HI-
LO-COM, press the MENU button to select the
remote. Press POOL or SPA to exit the Service
Setup mode.
Page 15

Publicité

Table des Matières
loading

Table des Matières