Temperature Scale Setup

1.
Make sure the control is in the OFF mode.
2.
To enter the User Setup mode, press and hold the
MENU button for 5 seconds.
3.
To select temperature scale, use the Up or Down
button to scroll through to display SELECT
USER SETUP TEMPERATURE SCALE . Press
the MENU button. The SELECT TEMP SCALE
°F (default temperature scale) appears, use the
Up or Down button to scroll through the scale
options. When you reach the desired temperature
scale, press the MENU button to select. Press
POOL or SPA to exit the User Setup mode.

Spa Timer Setup

1.
Make sure the control is in the OFF mode.
2.
To enter the User Setup mode, press and hold the
MENU button for 5 seconds.
3.
To select spa timer, use the Up or Down button to
scroll through to display SELECT USER SETUP
SPA TIMER . Press the MENU button. The
SELECT SPA TIMER CONTINUOUS (default
spa timer setting) is displayed. To turn the spa
on or off indefinitely, press the MENU button to
select.
To select the length of time for the spa to run,
use the Up or Down button to scroll to display
SELECT SPA TIMER TIME SELECTION . Press
the MENU button to select. The display SELECT
SPA TIME 01:00 HRS (default time setting) is
displayed. Use the Up or Down button to select
the length of time for the spa to run (between
00:15 to 23:00 hours incremented by 00:15
minutes). Press the MENU button to select how
long the spa will run. Press POOL or SPA to exit
the User Setup mode.

Display Light Setup

1.
Make sure the control is in the OFF mode.
2.
To enter the User Setup mode, press and hold the
MENU button for 5 seconds.
3.
To select display light setup, use the Up or Down
button to scroll through to display SELECT
USER SETUP DISPLAY LIGHT . Press the
MENU button. The SELECT DISPLAY LIGHT
2 MIN TIMEOUT (default display light setting) is
displayed. This option allows the display light to
turn off after 2 minutes. Press the MENU button
to select. Use the Up or Down button to scroll
to display SELECT DISPLAY LIGHT LIGHT
OFF , this option allows the display light to turn
|
Jandy
®
JRT Series Heat Pumps
off, press the MENU button to select. Use the
Up or Down button to scroll to display SELECT
DISPLAY LIGHT LIGHT ON , this option allows
the display light to turn on, press the MENU
button to select. Press POOL or SPA to exit the
User Setup mode.
5.5
Make sure the control is in the ON mode (POOL or
SPA), press and hold the Up and Down buttons for 5
seconds. The set point will be locked and the control
will operate in the mode it was in when the Set Point
Lockout occurred. If an attempt to change the set point
is made while the control is in Set Point Lockout, the
control will display SET POINT LOCKED . To unlock
the Set Point Lockout, press and hold the Up and Down
buttons for 5 seconds. The unit will display SET POINT
UNLOCKED .
5.6
The water pressure switch should be adjusted
to turn the heater off when the pump is off.
Setting the switch to close at too low of a flow
can damage the appliance. Adjust the switch
to turn the heater off, not on.
The pressure switch is preset at the factory for
activation at 3 psi (21 kPa). This is the minimum setting
for the water pressure switch and works for all basic
installations. Only adjust the water pressure switch if
the heat pump does not operate when the proper flow
is applied to unit or if the heat pump does not shut
off when the filter pump is off. Occasionally, unusual
plumbing configurations or necessary restrictions in
the plumbing may cause pressure sensing problems. In
these rare situations, the plumbing system configuration
may require adjustment of the water pressure switch.
Adjustment of the pressure switch may be necessary
if any part of the filter system piping is 3 feet (1 m) or
more above the top of the heat pump jacket.
Do not adjust the pressure switch if the heat pump is
installed more than 5 feet (1.5 m) above or 10 feet
(3 m) below the pool surface. Consult your local
Zodiac
Figure 14. Winterizing the JRT Heat Pump
Installation and Operation Manual

Set Point Lockout

Water Pressure Switch Adjustment

CAUTION
dealer for recommendations.
®