Install Face Plate
Chimney
ContACt yoUR LoCAL BUILDInG AUtHoRIty foR
APPRoVED MEtHoDS of InStALLAtIon.
1. A chimney connector shall not pass through an attic,
roof space, closet, floor, ceiling or similar concealed
space. Where passage through a wall or partition of
combustible constructions is desired, the installation
shall conform to CAN/CSA B365 (in Canada). In the
US, check with local building officials for requirements
in your area.
2. It is advisable to have your masonry chimney inspect-
ed for deterioration such as cracks and crumbling mor-
tar before you install your unit.
6
Figure 5
Face Plate Assembly
4
1
2
ST1024
Spring #10
ST1025
7
6
Figure 7
Chimney Liner
3. To help ensure a good draft, the top of the chimney
should be at least 3 feet (914 mm) above the point
9
of penetration through the roof, and be at least 2 feet
(610 mm) higher than any point of the roof within 10
feet (3 m).
4. Do not use makeshift compromises during installa-
tion.
5. Do not remove bricks or mortar from the fireplace.
Canada: This fireplace insert must be installed with a con-
tinuous chimney liner of 6" (152 mm) minimum diameter
extending form the flue collar to the top of the chimney.
The chimney liner must conform to the class 3 require-
ments of CAN/ULC-S635 Standard for lining systems for
existing masonry or factory-built chimneys and vents, or
CAN/ULC-S640 Standard for lining systems for new ma-
sonry chimneys. (Fig. 7)
USA: This fireplace insert must be connected to:
1. A chimney complying with the requirements for type
HT chimneys in the Standard for Chimneys, Factory-
built, Residential type and building Heating Appliance,
UL103, or
2. A code-approved masonry chimney with flue liner.
Alternate Chimney Installation
Applies to USA onLy
Contact your local building authority for approved meth-
ods of installation.
WARnInG: This fireplace insert must be connected to:
A chimney complying with the requirements for type HT
chimneys in the Standard for Chimneys, Factory-built,
Residential Type and building Heating Appliance, UL103
6" (152 mm) Min.
Dia. Stainless
Steel Flexible
Liner
notES: A stain-
less steel adapter
is recommended for
fastening the stainless
steel flexible liner to
the collar.
Male or crimped end
of the adapter must
be installed inside the
flue collar. Drill flue
collar to permanently
fasten stainless steel
adapter using a mini-
mum of 3 screws.
Fasten stainless steel
ST1026
chimney liner to the
stainless steel adapter
using manufactures
instructions.