loading

Sommaire des Matières pour Dimplex LI 22HS

  • Page 1 All manuals and user guides at all-guides.com LI 22HS LI 26HS Montage- und Gebrauchsanweisung Installation and Operating Instructions Instructions d’installation et d’utilisation Luft/Wasser- Air-to-Water Pompe à chaleur Wärmepumpe für Heat Pump for air-eau pour Innenaufstellung Indoor Installation installation intérieure Bestell-Nr. / Order no. / N de commande : 452158.66.09...
  • Page 2 All manuals and user guides at all-guides.com...
  • Page 3: Table Des Matières

    Reinigung / Pflege ........................D-7 8.1 Pflege..............................D-7 8.2 Reinigung Heizungsseite ........................D-7 8.3 Reinigung Luftseite ..........................D-8 Störungen / Fehlersuche ......................D-8 10 Außerbetriebnahme / Entsorgung ....................D-8 11 Geräteinformation ........................D-9 12 Garantieurkunde......................... D-10 Anhang / Appendix / Annexes ......................A-I www.dimplex.de...
  • Page 4: Bitte Sofort Lesen

    All manuals and user guides at all-guides.com Bitte sofort lesen Verwendungszweck der Wärmepumpe 1.1 Wichtige Hinweise 2.1 Anwendungsbereich ACHTUNG! Die Wärmepumpe darf beim Transport nur bis zu einer Neigung von 45° Die Hochtemperatur-Luft-Wasser-Wärmepumpe ist für die Sa- (in jeder Richtung) gekippt werden. nierung bestehender Heizungsanlagen einsetzbar, wenn Vor- lauftemperaturen bis 75 °C erforderlich sind.
  • Page 5: Lieferumfang

    Warmwasserbereitung und die sicherheitstechnischen Einrich- tungen. Der bauseits anzubringende Außentemperaturfühler incl. Befes- tigungsmaterial liegt dem Regler bei. Funktionsweise und Handhabung des Wärmepumpenreglers sind in der dazu beiliegenden Gebrauchsanweisung beschrie- ben. Verdampfer Rückschlagventil Ventilator Schaltkasten Pressostate Verflüssiger Filtertrockner Verdichter R404A Verdichter R134a www.dimplex.de...
  • Page 6: Transport

    All manuals and user guides at all-guides.com Transport Aufstellung ACHTUNG! 5.1 Allgemein Die Wärmepumpe darf beim Transport nur bis zu einer Neigung von 45° (in jeder Richtung) gekippt werden. Das Gerät ist grundsätzlich in Innenräumen auf einer ebenen, glatten und waagrechten Fläche aufzustellen. Dabei sollte der Der Transport zum endgültigen Aufstellungsort sollte mit Holz- Rahmen rundum dicht am Boden anliegen, um eine geeignete rost erfolgen.
  • Page 7: Montage

    Anschlussstutzen an der Ansaug- und Ausblasseite des Ver- dampfers mit 4 Sechskantschrauben M8x16 an den vorgesehe- nen Gewindelöchern befestigt. Dabei ist zu beachten, dass beide Luftkanalstutzen nur mit der Isolierung und nicht mit dem Außen- blech in Berührung kommen. www.dimplex.de...
  • Page 8: Elektrischer Anschluss

    All manuals and user guides at all-guides.com Inbetriebnahme Frostschutz Bei Wärmepumpen, die frostgefährdet aufgestellt sind, sollte eine manuelle Entleerung (siehe Bild) vorgesehen werden. So- 7.1 Allgemein fern Regler und Heizungsumwälzpumpe betriebsbereit sind, ar- beitet die Frostschutzfunktion des Reglers. Bei Außerbetrieb- Um eine ordnungsgemäße Inbetriebnahme zu gewährleisten, nahme der Wärmepumpe oder Stromausfall ist die Anlage zu sollte diese von einem vom Werk autorisierten Kundendienst...
  • Page 9: Reinigung / Pflege

    Danach muss mit geeigneten neutralisierenden Mitteln gründlich nachgespült werden, um Beschädigungen durch eventuell im System verbliebene Reinigungsmittelreste zu verhindern. Die Säuren sind mit Vorsicht anzuwenden und es sind die Vor- schriften der Berufsgenossenschaften einzuhalten. Im Zweifelsfall ist mit dem Hersteller des Reinigungsmittels Rücksprache zu halten! www.dimplex.de...
  • Page 10: Reinigung Luftseite

    All manuals and user guides at all-guides.com 10 Außerbetriebnahme / 8.3 Reinigung Luftseite Entsorgung Luftkanäle, Verdampfer, Lüfter und Kondensatablauf sind vor der Heizperiode von Verunreinigungen (Blätter, Zweige usw.) zu rei- nigen. Dazu ist die Wärmepumpe an der Frontseite zuerst unten Bevor die Wärmepumpe ausgebaut wird, ist die Maschine span- und dann oben zu öffnen.
  • Page 11: Geräteinformation

    All manuals and user guides at all-guides.com 11 Geräteinformation Geräteinformation für Luft/Wasser-Heiz-Wärmepumpen Typ- und Verkaufsbezeichnung LI 22HS LI 26HS Bauform Schutzart nach EN 60 529 für Kompaktgerät bzw. Heizteil IP 21 IP 21 Aufstellungsort Innen Innen Leistungsangaben Temperatur-Betriebseinsatzgrenzen: bis 75 / ab 18 bis 75 / ab 18 Heizwasser-Vorlauf / -Rücklauf...
  • Page 12: Garantieurkunde

    Teile ersetzt werden. Durch Art oder Ort des Einsatzes des Systemtechnik-Kundendienst erfahren Sie über die zentrale Ser- Gerätes oder schlechte Zugänglichkeit des Gerätes bedingte au- vicehotline der Glen Dimplex Deutschland GmbH. ßergewöhnliche Kosten der Mängelbeseitigung werden nicht übernommen. Der freie Gerätezugang muss durch den Endab- Glen Dimplex Deutschland GmbH nehmer gestellt werden.
  • Page 13 Maintenance / Cleaning ........................E-7 8.1 Maintenance ............................E-7 8.2 Cleaning the Heating System ......................... E-7 8.3 Cleaning the Air System ......................... E-7 Faults / Trouble-Shooting ......................E-8 10 Decommissioning/Disposal ......................E-8 11 Device Information ........................E-9 Anhang / Appendix / Annexes ......................A-I www.dimplex.de...
  • Page 14: Please Read Immediately

    All manuals and user guides at all-guides.com Please Read Purpose of the Heat Immediately Pump 1.1 Important Information 2.1 Application The high temperature air-to-water heat pump can be used for ret- ATTENTION! rofitting existing heating systems when flow temperatures of up When transporting the heat pump, ensure that it is not tilted more than to 75 °C are required.
  • Page 15: Scope Of Delivery

    The enclosed operating instructions describe the function and use of the heat pump controller. Evaporator Check valve Ventilator Switch box Pressure switches Liquifier Filter dryer R404A compressor R134a compressor www.dimplex.de...
  • Page 16: Transport

    All manuals and user guides at all-guides.com Transport Set-up ATTENTION! 5.1 General Information When transporting the heat pump, ensure that it is not tilted more than 45° (in any direction). The unit must be installed indoors on a level, smooth and hori- zontal surface.
  • Page 17: Installation

    4 M8 x 16 hexagon bolts in the threaded holes provided. When doing this, ensure that both air duct stubs only touch the insula- tion. There should be no contact with the external sheeting. www.dimplex.de...
  • Page 18: Electrical Connection

    All manuals and user guides at all-guides.com Start-Up Antifreeze A method of manual drainage (see illustration) should be pro- vided for heat pumps which are exposed to frost. The antifreeze 7.1 General Information function of the heat pump controller is active whenever the con- troller and the heat circulating pump are ready for operation.
  • Page 19: Maintenance / Cleaning

    In the event that op- Chapter 4. erating malfunctions due to contamination still occur, the system To prevent the evaporator and the condensate tray from being should be cleaned as described below. damaged, do not use hard or sharp objects for cleaning. www.dimplex.de...
  • Page 20: Faults / Trouble-Shooting

    All manuals and user guides at all-guides.com Faults / Trouble- 10 Decommissioning/ Shooting Disposal This heat pump is a quality product and is designed for trouble- Before removing the heat pump, disconnect it from the power free and maintenance-free operation. In the event that a fault source and close all valves.
  • Page 21: Device Information

    All manuals and user guides at all-guides.com 11 Device Information Device information for air-to-water heat pumps for heating purposes Type and order code LI 22HS LI 26HS Design Degree of protection according to EN 60 529 for compact devices IP21...
  • Page 22 All manuals and user guides at all-guides.com Table des matières A lire immédiatement ! ......................... F-2 1.1 Remarques importantes.......................... F-2 1.2 Dispositions légales et directives ......................F-2 Utilisation de la pompe à chaleur....................F-2 2.1 Domaine d’utilisation..........................F-2 2.2 Fonctionnement ............................F-2 Fourniture ............................
  • Page 23: Lire Immédiatement

    Les enfants doivent être surveillés pour éviter qu'ils ne jouent avec l'appareil. www.dimplex.de...
  • Page 24: Fourniture

    All manuals and user guides at all-guides.com Fourniture 3.2 Boîtier électrique Le boîtier électrique est monté dans la pompe à chaleur. Le boî- 3.1 Appareil de base tier électrique peut être rabattu après avoir retiré l’habillage fron- tal inférieur et dévissé la vis de fixation se trouvant en haut à La pompe à...
  • Page 25: Transport

    à chaleur au sys- tème de chauffage à l'aide d’un tuyau flexible. Les conduits d’air utilisés doivent être découplés de la pompe à chaleur d’un point de vue acoustique pour éviter les transmis- sions de bruit sur les conduits. www.dimplex.de...
  • Page 26: Montage

    All manuals and user guides at all-guides.com Montage 6.1 Remarques d’ordre général Les raccordements suivants doivent être réalisés sur la pompe à chaleur : Aspiration/évacuation d’air Circuits départ et retour de l’installation de chauffage Ecoulement des condensats Câble de commande vers régulateur de pompe à chaleur Alimentation électrique 6.2 Prise d’air ATTENTION !
  • Page 27: Protection Antigel

    âmes simples (sonde de retour intégrée) au régulateur de pompe à chaleur nécessaire à la commande. Des instructions plus pré- cises se trouvent dans les instructions d'utilisation du régulateur de pompe à chaleur. Pour des informations plus détaillées, cf. schémas électriques en annexe. www.dimplex.de...
  • Page 28: Nettoyage / Entretien

    All manuals and user guides at all-guides.com Nettoyage / entretien Température Différence de température max. de départ entre circuits départ et retour du 8.1 Entretien chauffage à -20 °C -15 °C Il faut éviter d’appuyer ou de déposer des objets sur l’appareil -14 °C -10 °C afin de protéger la laque.
  • Page 29: Nettoyage Côté Air

    à chaleur. Si vous n'êtes pas en mesure de remédier vous-même au dysfonction- nement, veuillez vous adresser au service après-vente compé- tent. ATTENTION ! Les travaux sur la pompe à chaleur doivent être effectués uniquement par des techniciens qualifiés et agréés. www.dimplex.de...
  • Page 30: Informations Sur Les Appareils

    All manuals and user guides at all-guides.com 11 Informations sur les appareils Informations sur les pompes à chaleur air/eau pour chauffage Désignation technique et commerciale LI 22HS LI 26HS Forme Type de protection selon EN 60 529 pour app. compact ou élt. de chauffe IP 21...
  • Page 31 Maßbild / Dimension Drawing / Schéma coté ................A-II Diagramme / Diagrams / Diagrammes..................A-III 2.1 Kennlinien / Characteristic Curves / Courbes caractéristiques LI 22HS..........A-III 2.2 Kennlinien / Characteristic Curves / Courbes caractéristiques LI 26HS..........A-IV Stromlaufpläne / Circuit Diagrams / Schémas électriques............A-V 3.1 Steuerung / Control / Commande ......................A-V...
  • Page 32: Maßbild / Dimension Drawing / Schéma Coté

    All manuals and user guides at all-guides.com 1 Maßbild / Dimension Drawing / Schéma coté A-II...
  • Page 33: Diagramme / Diagrams / Diagrammes

    All manuals and user guides at all-guides.com 2 Diagramme / Diagrams / Diagrammes 2.1 Kennlinien / Characteristic Curves / Courbes caractéristiques LI 22HS www.dimplex.de A-III...
  • Page 34: Kennlinien / Characteristic Curves / Courbes Caractéristiques Li 26Hs

    All manuals and user guides at all-guides.com 2.2 Kennlinien / Characteristic Curves / Courbes caractéristiques LI 26HS A-IV...
  • Page 35: Stromlaufpläne / Circuit Diagrams / Schémas Électriques

    All manuals and user guides at all-guides.com 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung / Control / Commande www.dimplex.de...
  • Page 36: Last / Load / Charge

    All manuals and user guides at all-guides.com 3.2 Last / Load / Charge A-VI...
  • Page 37: Anschlussplan / Circuit Diagram / Schéma Électrique

    All manuals and user guides at all-guides.com 3.3 Anschlussplan / Circuit Diagram / Schéma électrique www.dimplex.de A-VII...
  • Page 38: Legende / Legend / Légende

    All manuals and user guides at all-guides.com 3.4 Legende / Legend / Légende Pressostat Abtauende Defrost end controller Pressostat fin de dégivrage Pressostat HGB-Ventil Pressure switch, HGB valve Pressostat vanne HGB Pressostat Hochdruck High-pressure switch Pressostat haute pression Pressostat Hochdruck, 2. Kältekreis High-pressure switch, refrigerating circuit 2 Pressostat haute pression, circuit froid 2 Pressostat Niederdruck...
  • Page 39: Hydraulische Prinzipschemen / Hydraulic Plumbing Diagram / Schémas Hydrauliques

    All manuals and user guides at all-guides.com 4 Hydraulische Prinzipschemen / Hydraulic Plumbing Diagram / Schémas hydrauliques 4.1 Monoenergetische Anlage / Mono Energy System / Installation monoénergétique www.dimplex.de A-IX...
  • Page 40: Monoenergetische Anlage Und Warmwasserbereitung / Mono Energy System And Domestic Hot Water Preparation / Installation Monoénergétique Et Production D'eau Chaude

    All manuals and user guides at all-guides.com 4.2 Monoenergetische Anlage und Warmwasserbereitung / Mono Energy System and Domestic Hot Water Preparation / Installation monoénergétique et production d‘eau chaude...
  • Page 41: Legende / Legend / Légende

    External wall sensor Sonde de paroi extérieure Rücklauffühler Return flow sensor Sonde de retour Warmwasserfühler Hot water sensor Sonde d’eau chaude Elektroverteilung Electrical distribution system Distributeur courant électrique Kaltwasser Cold water eau froide Warmwasser Domestic hot water Eau chaude www.dimplex.de A-XI...
  • Page 42: Konformitätserklärung / Declaration Of Conformity / Déclaration De Conformité

    All manuals and user guides at all-guides.com 5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité A-XII...
  • Page 43 All manuals and user guides at all-guides.com www.dimplex.de A-XIII...
  • Page 44 All manuals and user guides at all-guides.com Glen Dimplex Deutschland GmbH Irrtümer und Änderungen vorbehalten. Geschäftsbereich Dimplex Subject to alterations and errors. Am Goldenen Feld 18 Sous réserve d’erreurs et modifications. D-95326 Kulmbach +49 (0) 9221 709 565 www.dimplex.de...