Product Overview
Description
The charge controller protects the battery from being overcharged
by the solar energy as well as from being overused by the loads.
The charging characteristics include several stages which include
automatic adaptation to the ambient temperatures.
System Voltage
This product is intended for use at 12 V and 24 V system voltage.
Battery Type
The ECO-N-T is suitable for use with lead acid batteries (vented,
GEL, or AGM type).
Low Voltage Disconnect Function
To prevent the battery against over-discharge this function
automatically switches off the load output at a battery voltage lower
than 11.0 V (12 V systems) or 22.0 V (24 V systems). As soon as
the battery reaches a voltage of 12.8 V (12 V systems) or 25.6 V
(24 V systems), the load output is switched on again.
Regulatory Information
Operation Notes
Warning: Indicates high voltage. Use caution when
performing task.
Caution: Indicates a critical procedure for safe operation.
Note: Indicates important information for safe and easy
installation and operation.