Thank you very much for buying a Phocos product. With your new CIS-CU-
LCD remote control you own a state-of-the-art device which was developed
according to the latest technical standards available.
This manual gives important recommendations for installing, using and
programming etc. In your own interest, please read it carefully.
General Product Description
Configures CIS charge controllers via infrared data link
Simple and clear configuration interface
User interface: LC display, keys
Power supply: 2x AAA batteries
Functions
Sets controller settings and sends all settings to controller
Reads settings from controller and LC display
Saves all settings to local file
Downloads local file for sending directly or setting up again
Keys and Display
Key function
Display
Key
icon
/
Power on (auto power-off )
Selects single or dual load controller. If your
controller is a single load type*, please select single
Controller
4
load icon before setting up, if it is a dual load
type
type**, please select dual load icon. Press it, one
load and two load icons will be displayed in turns.
Selects flooded or GEL battery and press "OK". Icons
Battery
5
will flash in turns. Press "OK" and select one battery
type
type.
All manuals and user guides at all-guides.com
Function
6
Selects load 1 or dimming for single load controller
or load 2 for dual load controller. When using a
6, 12
single load controller, press once "Load select" key.
Load select
icon 6 is displayed, first load can be set. Press again.
icon 12 is displayed, dimming can be set.
If using a dual load type controller, press this key to
6, 9
select between load 1 and load 2.
Sets up timer mode based on dusk & dawn or
based on middle of night. If the icon of load 1 (6) is
displayed, this timer mode is the timer mode of
load 1. If the icon of load 2 (9) is displayed, it is the
timer mode of load 2. If the dimming icon 12
"Dimming" is displayed, it is the timer mode for
Time mode
16
dimming.
Note: If both evening and morning times are
adjusted to "OFF" or morning time is adjusted to
D2D, the timer mode is set to D2D and cannot be
adjusted. If you want to adjust the timer mode,
please adjust evening time and morning time in
hours instead of OFF or D2D*** first!
Sets up low battery voltage disconnect protection
mode to LVD or SOC. When the controller is a single
load type, "load 1" (icon 6) or "Dimming" (icon 12) is
displayed. Press this key, select either SOC or LVD,
and press "+" or "-" to modify its value, then press
Protect
7, 13,
"OK" to confirm. When the controller is a dual load
mode
14
type, display of icon 6 is for load 1 protection and
display of icon 9 is for load 2 protection.
LVD voltage range: 11.0-11.9/22.0-23.8 V (step:
0.1/0.2 V)
SOC range: 1-6 (step 1)
Sets up system reconnect voltage. Press "+" or "-",
Reconnect
13, 14,
adjust its value then press "OK" to confirm.
voltage
15
Adjustment voltage range: 11.0–12.8/22.0–25.6 V
(step: 0.1/0.2 V)
Sets up night detection voltage and dimming
value. Press once to adjust night detection voltage
by selecting "+" or "-", then "OK". Press again to set
up dimming value percentage. If the controller is a
Night
8, 12,
dual load type, dimming cannot be set. If it is a
detect
13, 14
single load type and "Dimming" (icon 12) is
Dimming
displayed, press once for night detection. Press
value
again for dimming value percentage. You can
adjust dimming percentage value by pressing "+"
or "-", and "OK".
Night detection voltage range: 2.5-10/5.0-20 V
(step: 0.5/1.0 V)
Dimming value range: 0% - 100% (step: 10% )
Sets up evening time and morning time. Press once
to set up evening hours by selecting "+" or "-", and
"OK", adjust value. Press again to set up morning
hours the same way.
Evening
If load 1 (icon 6) is displayed, these hour values are
time
10, 11,
for load 1 on/off time. If load 2 (icon 9) is displayed,
Morning
14
it is for the load 2 on/off time. If icon 12 "Dimming"
time
is displayed, these hour values are for dimming
on/off time of single controller!
Evening hours: 0-15h OFF
Morning hours: 0-14h D2D*** OFF
Increases the value of LVD / SOC / Reconnect
+
/
voltage / Night detection voltage / Dimming
percentage / Evening time / Morning time
Decreases the value of LVD / SOC / Reconnect
-
/
voltage / Night detection voltage / Dimming
percentage / Evening time / Morning time
Confirms the modified value of LVD / SOC /
Reconnect voltage / Night detection voltage /
OK
/
Dimming percentage / Evening time / Morning
time
Transmits all settings to the controller. When
transmitting, icon 3 "Transmit" flashes. If the
transmission was successful, icon 2 "OK" flashes 5 times.
Send
1, 2, 3
If an error occurred, icon 1 "ERROR" is displayed. Make
sure to program only one controller at a time.
Save
20, 21 Save all settings into a file. After setting up, press
once for saving function. Save the file as "1", "2", or