Kübler CODIX 54U Notice De Mise En Service page 20

Compteur à affichage électronique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.8 Operating mode (time meter)
*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units
4.9 Decimal point (time meter)
20
Time unit: seconds (accu-
racy depending on posi-
tion of the decimal point*)
Time unit: minutes (accu-
racy depending on posi-
tion of the decimal point*)
Time unit: hours (accura-
cy depending on position
of the decimal point*)
Time units:
Hours:Minutes:Seconds
(decimal point setting is
ignored)
The decimal point defines
the resolution of the pro-
grammed time unit.
0
1
0.0
1/10
(0,1)
0.00
1/100 (0,01)
0.000 1/1000 (0,001)
4.10 RESET mode (time meter)
4.11 End of programming
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.

Publicité