OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
1.­ Check­the­heater­for­possible­shipping­damage.­If­any­is­found,­
immediately­notify­the­factory.
2.­ Follow­all­of­the­"Precautions".­
3.­ Connect­the­POL­fitting­of­hose­and­regulator­assembly­to­the­
propane­cylinder­by­rotating­the­POL­nut­counterclockwise­into­
the­propane­cylinder's­valve­outlet­and­securely­tighten­with­a­
wrench.
4.­ Connect­the­hose­to­the­heater­by­rotating­the­hose­fitting­
clockwise.
5.­ Securely­tighten­all­gas­connections.
6.­ Open­the­cylinder's­gas­valve­and­check­all­gas­connections­
with­a­soap­and­water­solution.­DO­NOT­USE­A­FLAME.
7.­
Connect­power­cord­to­well-grounded­115V,­60­Hz,­1Ø­source­
of­power.
8.­ When­using­an­extension­cord,­make­certain­that­it­is­a­3-wire­
(grounded)­cord­of­proper­wire­size,­minimum­length­of­6­ft­
(1.83m).
START
THE HEATER POWER CORD MUST BE CONNECTED TO
1.
A GROUNDED 115V, 60HZ, 1Ø POWER SOURCE BEFORE
HEATER IGNITION­and­always­allow­heater­fan­(blower)­to­run­
for­20­seconds­to­purge­fuel.
2.­ Open­propane­supply­valve­on­propane­tank­slowly.­­Note:­­If­
not­opened­slowly,­excess-flow­check­valve­on­propane­tank­will­
stop­gas­flow.­­If­this­happens,­close­propane­supply­valve­and­
open­again­slowly.­­Wait­15­seconds­before­­­­Step­3.
3.­ Push­and­hold­automatic­control­valve­button.­­Push­piezo­
ignitor­button­repeatedly­until­the­burner­lights.
4.­ After­the­burner­lights,­keep­the­gas­valve­button­depressed­
for­30­seconds­then­release­and­the­heater­will­continue­to­
operate.
WARNING:­­Be­sure­motor­and­fan­are­running­before­pushing­
in­automatic­control­valve­button.­­Flames­could­flash­outside­
heater­or­internal­damage­to­heater­may­result­if­motor­and­fan­
are­not­running.
STOP
1.­ Securely­close­valve­on­the­propane­cylinder.
2.­ Continue­to­operate­heater­until­all­fuel­in­the­hose­has­burned.
3.­ Unplug­the­power­cord.
CAUTION:­­Always­shut­off­fuel­supply­before­disconnecting­
electrical­power.
RESTART AFTER SAFETY SHUTDOWN
1.­ Securely­close­valve­at­propane­cylinder.­­Unplug­power­cord.
2.­ Wait­5­minutes.­
3.­ Restart­following­"START"­procedure.
Forced Air Propane Construction Heater

MAINTENANCE AND STORAGE

1.­ The­heater­should­be­inspected­before­each­use,­and­at­least­
annually­by­a­qualified­person.
2.­ Before­each­use,­check­the­soft­"O"­ring­seat­at­the­bullnose­
of­the­POL­fitting.­If­the­"O"­ring­is­cut,­scuffed,­or­otherwise­
damaged,­replace­it­with­part­number­6681.
3.­ Turn­off­the­gas­at­the­LP-gas­supply­cylinder(s)­when­the­heater­
is­not­in­use.
4.­ When­the­heater­is­to­be­stored­indoors,­the­connection­
between­the­LP-gas­supply­cylinder(s)­and­the­heater­must­
be­disconnected­and­the­cylinder(s)­removed­from­the­heater­
and­stored­out­of­doors­and­in­accordance­with­Chapter­5­of­
the­standard­for­Storage­and­Handling­of­Liquefied­Petroleum­
Gases­ANSI/NFPA­58­and­CSA­B149.1,­Natural­Gas­and­Propane­
Installation­Code.
SERVICING
A­hazardous­condition­may­result­if­a­heater­is­used­that­has­been­
modified­or­is­not­functioning­properly.­When­the­heater­is­working­
properly:
The­flame­is­contained­within­the­heater.
*­­ The­flame­is­essentially­blue­with­perhaps­some­yellow­tipping.
There­is­no­strong­disagreeable­odor,­eye­burning­or­other­
physical­discomfort.
There­is­no­smoke­or­soot­internal­or­external­to­the­heater.
There­are­no­unplanned­or­unexplained­shut­downs­of­the­
heater.
The­parts­lists­and­exploded­view­show­the­heater­as­it­was­
constructed.­Do­not­use­a­heater­which­is­different­from­that­shown.­
In­this­regard,­use­only­the­hose,­regulator­and­cylinder­connection­
fitting­(called­a­POL­fitting)­supplied­with­the­heater.­IMPORTANT
Match­the­color­stripe­on­the­hangtag­attached­to­the­hose­assembly­
with­the­color­on­the­label­located­near­the­propane­inlet­fitting­on­
the­heater.­Do­not­use­alternates.­For­this­heater,­the­regulator­must­
be­set­as­shown­in­"specifications".­If­there­is­any­uncertainty­about­
the­regulator­setting,­have­it­checked.
A­heater­which­is­not working­right­must­be­repaired,­but­only by a
trained,­experienced­service­person.
In-warranty­products­will­be­repaired­with­no­charge­for­either­parts­
or­labor.­Please­include­a­brief­statement­indicating­date,­place­of­
purchase,­the­nature­of­the­problem­and­proof­of­purchase.
Out-of-warrranty­products­will­be­repaired­with­a­charge­for­parts­and­
labor.
5
Operating Instructions and Owner's Manual

Publicité

Table des Matières
loading

Table des Matières