Installation And Connection - Oase AquaMax Eco Classic 2500 Notice D'emploi

Masquer les pouces Voir aussi pour AquaMax Eco Classic 2500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
− Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the identifi-
cation H05RN-F. Extension cables must meet DIN VDE 0620.
− Protect the plug connections from moisture.
− Only plug the unit into a correctly fitted socket.
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating instruc-
tions.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
− The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
− Only operate the unit if no persons are in the water!
− Keep the socket and power plug dry.
Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of pace-
makers.

Installation and connection

A
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries due to operation of this unit in a swimming pond.
Protective measures:
− Do NOT use this unit in a swimming pond.
− Adhere to national and regional regulations.
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Aquamax Eco Classic 2500
Operating the unit in the pond
B
The pump is in the pond. The return system, e.g. a pond filter, is connected to the pump outlet.
8.
0.
How to proceed:
C
1. Screw the stepped hose adapter to the outlet.
− Shorten and deburr the stepped hose adapter such that the adapter diameter matches the hose diameter used.
2. Connect the hose with the stepped hose adapter and secure with a hose clip.
Aquamax Eco Classic 3500/5500/8500/11500/14500
Operating the unit in the pond
B
The pump is in the pond. The return system, e.g. a pond filter, is connected to the pump outlet.
3.
0.
How to proceed:
D
1. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
− Shorten and deburr the stepped hose adapter such that the adapter diameter matches the hose diameter used.
− Align the stepped hose adapter prior to tightening the union nut.
2. Connect the hose with the stepped hose adapter and secure with a hose clip.
- GB -
11

Publicité

Table des Matières
loading

Table des Matières