2.7 Using extension cords
Use only extension cords of a type approved for the application and with conductors of adequate cross section.
The power tool may otherwise lose performance and the extension cord may overheat. Check the extension cord for
damage at regular intervals. Replace damaged extension cords.
Recommended minimum conductor cross section and max. cable lengths
en
Conductor cross section
Mains voltage 110-120 V
2.8 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this application.
2.9 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled: The unit
must provide a power output in watts of at least twice the value printed on the type identification plate on the power
tool. The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in
the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and
starting boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching other
power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in damage to the
power tool.

3 Accessories

The list of insert tools can be found in Section 2 under "Possible applications".
Designation
Keyless chuck
Key chuck
Chuck key (with keyed chuck)
Dust removal system

4 Technical data

Right of technical changes reserved.
Power tool
Rated voltage
Rated current input
Mains frequency
Weight of tool without side handle
Weight in accordance with EPTA procedure 01/2003
Dimensions (L x W x H)
Speed in 1st gear under no load
Speed in 2nd gear under no load
Hammering speed
Chuck ∅
Maximum torque, 1st gear
Maximum torque, 2nd gear
4
16 AWG
50 ft
Short designation
TE DRS‑S
UH 700
120 V
8.0 A
50...60 Hz
2.4 kg (5.2 lbs)
2.6 kg (5.7 lbs)
342 mm (13.46") x 86 mm (3.39") x 205 mm
(13 x 3 x 8 in)
900/min
2,500/min
40,000/min
1.5...13 mm (¹/₁₆ to ½")
80 Nm (59 lb/ft)
29 Nm (21 lb/ft)
14 AWG
100 ft
Item number, description
274077
274079
274081
340602
12 AWG
150 ft

Publicité