- To prevent any danger or malfunction, the size of electrical control components
connected to the motor must be compatible with the electrical features of the motor.
- means for disconnection must be incorporated in the fixed wiring in accordance with
the national installation standards.
- The selectors inverting the direction of rotation of the motor must be provided with
mechanical interlocking.
- Invert the brown and the black conductor to change the direction of rotation.
- neVer connect two or more motors to the same selector (parallel connection) If you
couple two motors, use multi-poles selectors only.
- neVer connect two or more selectors to the same motor.
- for outdoor use, provide the appliance with a supply cable
with designation h05rr-f containing at least 2% of
carbon.