Communicator Receiver/Panel
3G2080 (R) E
Receiver
LE2080 (R)
TL2803G (R) E
TL280LE (R)
TL280(R)E
TL280LE-EU
Panel
LE2080-EU
NOTE: Enter [*][8][Installer Code][900] at keypad to view the panel version number.
Encryption
The communicator uses 128 Bit AES encryption. Encryption can only be enabled from the monitoring station receiver.
Each receiver (Ethernet 1 and 2, Cellular 1 and 2) can independently have encryption enabled or disabled. When
encryption is enabled, the central station will configure the device to encrypt communications the next time the com-
municator module sends communication to that receiver.
NOTE: Packets will start being encrypted only after the next event is sent to that receiver, or if the unit is restarted.
Before leaving the installation site, the communicator TL2803(R) E / TL280LE(R) Ethernet line shall be connected
via an approved (acceptable to the local authorities) Network Interface Device (NID). All wiring shall be performed
according to the local electrical codes.
Communicator Installation Configuration
This alarm communicator shall be installed by skilled persons only (skilled person is defined as a person having the
appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed
to in performing a task and can also take measures to minimize the risks to that person or other persons). The Com-
municator shall be installed and used within an environment that provides the pollution degree max 2, overvoltages cat-
egory II, in non- hazardous, indoor locations only. This manual shall be used with the installation manual of the panel
which is connected to the communicator. All instructions specified within the panel manual must be observed.
All the local rules imposed by local electrical codes shall be observed and respected during installation.
Installing the Ethernet Cable (TL Models Only)
A Category 5 (CAT 5) Ethernet cable must be run from a source with Internet connectivity to the communicator module,
inside the panel. The communicator end of the cable must be terminated with an RJ45 plug, which will connect to the
communicator's RJ45 jack after the communicator is installed. All requirements for installation of CAT5 Ethernet cable
must be observed for correct operation of the communicator, including, but not limited to, the following:
Do NOT strip off cable sheathing more than required for proper termination.
l
Do NOT kink/knot cable.
l
Do NOT crush cable with cable ties.
l
Do NOT untwist CAT5 pairs more than ½ in. (1.2cm).
l
Do NOT splice cable.
l
Do NOT bend cable at right angles or make any other sharp bends.
l
Do NOT use CAT6 cable.
l
NOTE: CAT5 specification requires that any cable bend must have a minimum 2 in. (5 cm) bend radius. Maximum
length of CAT 5 cable is 328 ft. (100 m).
Table 5: Compatible Receivers and Panels
Sur-Gard System I-IP Receiver, version 1.13+
l
Sur-Gard System II Receiver, version 2.10+
l
Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
l
Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
l
Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver)
l
HS2016
l
HS2016-4
l
HS2032
l
HS2064
l
HS2128
l
Pre Installation Configuration
Description
8