WARNING! - 3G2080(R)E/TL2803G (R)E/LE2080(R)/TL280LE(R) modules are power limited. Do not route any
wiring over the circuit board. Maintain at least 1in. (25.4mm) separation between circuit board and wiring. A
minimum of ¼ in. (7mm) separation must be maintained at all points between non-power limited wiring and
power limited wiring.
3.
To wire the communicator to the panel, perform the following steps (See
a.
Disconnect both AC power and battery connections from the panel, and disconnect telephone line.
b.
Confirm that the SIM card is inserted in the holder and locked.
4.
Install Network Cable (TL models only). Route the CAT 5 Ethernet cable through back of the panel and plug it
into the communicator's RJ45 jack.
5.
Install the RS-232 connections (R models only). If using the communicator with a 3rd party device, wire the
connections as per Table 3.
NOTE: Before leaving the premises the Ethernet communication lines must first be connected to an approved type
NID (acceptable to local authorities). All wiring shall be performed according to the local electrical codes.
Figure 2: HS2016/2016-4/2032/2064/2128 Control Panel
1
2
3
Item
Description
1
PC-Link Cable Connector
Quad Band Whip Antenna - Use light
2
pressure to attach antenna
only
3
Screw
Figure 3
11