5.
When final panel/antenna location is determined, continue at the
NOTE: If the SIM card is not activated, placement test will indicate the signal strength of the nearest cellular tower.
NOTE: In between displaying signal strength, the signal strength LEDs will flash alternately if an inactive SIM card is
used. The flashing indicates that the module is attempting to attach to the cellular network and will only last
briefly.
Keypad Data Display
Section-Toggle Options:
l
toggle is OFF. (e.g., toggle options displays: [--3--6--]. Options 3 and 6 are ON, all others are OFF). Pressing keys 1
through 8 will alternately turn the toggle ON and OFF.
HEX/Decimal Data:
l
decimal followed by decimal equivalent (e.g., default [0BF5/3061]). Hexadecimal numbers are shown, with all lead-
ing zeroes, to the full field length defined for the number.
Entering HEX values at keypad
To enter HEX values at the keypad, press the [*] key before entering the HEX value. (e.g., to enter "C" at the keypad,
press [*][3])
Entering ASCII Characters at keypad
1.
Press [*] and use scroll buttons [<] [>] to display "ASCII Entry" on the LCD screen.
2.
Press [*] to select ASCII entry mode.
3.
Use the [<] [>] scroll keys to display the desired character and press [*] to save and exit ASCII.
4.
Repeat the steps above to enter another ASCII character.
HS2016/2016-4/2032/2064/2128 Initial Programming
For detailed information, refer to panel manual section 'Alternate Communicator Set-up'. These sections must be pro-
grammed at the panel keypad. Enter [*][8] [Installer Code] [Section Number]. Record any values that are modified
from their default, in the appropriate worksheets for the panel or communicator.
1.
[377]
In panel section
'Communication Delay', program 060 (seconds).
2.
[382]
In panel section
NOTE: If this option is OFF, the yellow status LED on the communicator will indicate 'Panel Supervision Trouble' (2
flashes) and the unit can not be programmed via the PC-LINK cable.
Activating the Communicator with C24 Communications
Installation of the 3G2080(R) E / LE2080(R) or TL2803G (R)E / TL280LE(R) in North America requires activation with
C24 Communications in order to operate. Please contact the central station (C24 Communications Master Reseller) to
confirm the required steps to activate / program the communicator.
All communicator options must be programmed via C24 Communications, except the following Ethernet options which
can also be programmed using the keypad or DLS:
[001] Ethernet IP Address
l
[002] Ethernet IP Subnet Mask
l
[003] Ethernet Gateway IP Address
l
NOTE: The SIM activation with the carrier can take several hours to complete. It is recommended the activation be com-
pleted prior to arrival on the customer site to avoid possible installation delays.
Once the SIM activation is complete, the communicator will automatically connect and download its programming from
C24 Communications.
The communicator has four on-board LED indicators. These include one yellow trouble LED, one red network con-
nection status LED and two green signal strength LEDs. The LED meaning is described in this section.
Yellow Trouble LED
This yellow LED will flash to indicate a trouble on the unit. The number of flashes indicates the type of trouble, refer to
the table below for trouble conditions.
Initial Panel Programming
The number is displayed when toggle is ON and the number is not displayed when
Values that are provided with two defaults, separated by a "/" character, use the format: hexa-
'Communication Variables', subsection
'Communicator Option 3' set option [5] ON.
Communicator Status LEDs
Table 8: Yellow Trouble Status LED
Initial Panel Programming
[002]
'Communication Delays', sub-subsection [1]
14
section.