BE24
15 - PAUSE TIME LEARNING
WARNINGS
• Values loaded by default:
- Total automatic reclosing time: 20 s;
- Pedestrian automatic reclosing time: 10 s;
• Be sure that the control unit has already successfully stored a stroke learning.
• Be sure that the gate has finished the closing manoeuvre before making the learning procedure.
• The time learning of total and pedestrian automatic reclosing time needs 2 different procedures.
Learning procedure of Total Pause Time
• Put DIP2_7 in ON.
• The FLASHING LIGHT glows steadily.
• Push START to start the pause time counting.
• The FLASHING LIGHT makes short flashes every second.
• Once passed the pause time chosen (MAX 127 s), give a new START command.
• The FLASHING LIGHT glows steadily to show the successful operation.
• Put DIP2_7 in OFF.
Learning procedure of Pedestrian Pause Time
• Put DIP2_7 in ON.
• The FLASHING LIGHT glows steadily.
• Push PED to start the pause time counting.
• The FLASHING LIGHT makes short flashes every second.
• Once passed the pause time chosen (MAX 127 s), give a new PED command.
• The FLASHING LIGHT glows steadily to show the successful operation.
• Put DIP2_7 in OFF.
16 - FLASHING LIGHT SIGNALS SUMMARY
Meaning
Opening
Closing
Photo 2 intercepted in stand-by
in presence of START command
Edge intercepted in stand-by
in presence of START command
Edge intercepted in pause in presence of
START command or at the closing beginning
Low Battery before closing (21V).
Low Battery before opening or closing(16V).
Pause time pre-cycle learning
Pause time learning
Signal
0,8s ON, 0,8s OFF continuous
0,4s ON, 0,4s OFF continuous
5 fast flashings
3 slow flashings
3 slow flashings
4 slow flashing
4 slow flashing
steady on
slow flashes every second
UK
Effect
The gate is opening
The gate is closing
When released it opens
Blocked closed door
Blocked open door
Blocked door
Blocked open door
Closed blocked door
Closed blocked door
23