WARNING
If the buoy is not positioned correctly in the pocket, correct release is not
guaranteed!

3. Troubleshooting

Problem
Buoy does not fit
into
the pocket
Velcro does
not close
CO2 cartridge is
pierced
immediately when
screwing in
CO2 cartridge can-
not be screwed in
or only screwed in
with much
difficulty
4. Storage, care, maintenance and disposal of your Beuchat Restube product
Lifespan & storability
Beuchat Restube products are designed to have a long lifespan and can be triggered from 50 to
250(*) times, depending on the version. Once used, the device is to be stored outside its packaging,
well ventilated and at a maximum temperature of 28°C. The maximum lifespan of the device is 5
years from the date of purchase, assuming that the care and maintenance instructions are followed.
If used frequently (more than once per week) or in tropical climates, the product lifespan may be
shorter. If humidity is high, the device should be removed from its box. Do not put Beuchat Restube
products on radiators and do not dry or store them in direct sunlight.
Care
Maintain your Beuchat Restube product after every use. Five minutes of your time will help to make
sure that you carry on being able to enjoy the product.
>>> Take the bladder out of its bag and check all parts for external damage: Bag, bladder, trigger,
trigger cord and CO2 cartridge. None of the components should show signs of heavy use, significant
rust or damage.
>>> Following use in saltwater or chlorinated water: Remove the bladder from its bag, and rinse
both in fresh water, ensuring that the oral valve is closed and that the cartridge is screwed in first. If
the product has become particularly dirty, wash it with mild detergent or a weak solution of lye and
rinse it with fresh water afterwards. Do not use cleaning agents which contain alcohol or solvents.
23
Position the folded buoy in the pocket so that the trigger mechanism is
facing the label with this
>>> The trigger cord must hang out of the pocket
Store the rest of the safety leash in the pocket next to the cartridge
Close the flap of the pocket
Close velcro 6.a on the inside
Fasten the split pin on the trigger cord alternating between the front
and back loops
Cause
Buoy is not fully emptied
Buoy is not folded
correctly Buoy is not
positioned correctly in
the pocket
The release lever was
not
switched before
screwing in the new CO2
cartridge
Dirt on the thread
or trigger
mechanism
symbol
Corrective action
> Empty buoy completely
> Observe packaging instructions
> Trigger mechanism must face
the label with this
> switch the release lever to
the green postition to avoid
piercing
cartridge.
> Clean the trigger mechanism
(*) Beuchat Restube freediving: Up to 200 times
symbol
the new CO2-