Télécharger Imprimer la page

Jotul FS 380 Série Manuel D'installation Et Données Techniques page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installation manual with technical data
1.0
Relationship to the authorities .....................11
2.0
Technical data ................................................11
3.0
Before installation ........................................ 12
4.0
Installation ................................................... 12
5.0
Installation completed ................................. 13
6.0
Optional Equipment ..................................... 13
Figures ..................................................................... 17
1.0 Relationship to the
authorities
The Jøtul FS 380 concept is a serial of freestanding products that
uses the Jøtul F 370 as the burn chamber and can be positioned
against inflammable walls at the distances described in fig.
1A+1B.
The installation of a fireplace must be carried out in compliance
with national laws and regulations. All local ordinances must be
observed when installing this product.
Contact your local building authorities regarding restrictions and
installation requirements. The product may not be used until it
has been inspected and approved by qualified personnel.
The surround comes with an Installation Manual that contains
technical data for the whole fireplace. The insert comes with an
Installation Manual that contains technical data for the insert
(see*). For day-to-day use, maintenance, service work, etc., please
refer to the General Use and Maintenance Manual.
* The Installation Manual for the Jøtul FS 380 concept must be
followed precisely with regard to the installation requirements
and information described in fig. 1A+1B and in «2.0 Technical
Data».
The product is documented as a freestanding product in
accordance with EN 13240.
The approval label for the freestanding product comes with the
Installation Manual for the surround. It should be affixed in a
suitably visible place.
2.0 Technical data
The surround is available in the following options:
Black paint and brushed steel.
Weight, surround, ca:
Weight, burn chamber, ca.:
Flue pipe dimension:
Ø 150 mm/177 cm
Height:
Width:
Depth:
Minimum distance to ceiling:
Height, centre smoke outlet, rear, ca.:
Connection height, ca.:
Location of external air supply:
Optional extras:
Technical data in acc. with EN 13240
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught: 12 Pa
Efficiency:
CO emissions (13% O
):
2
Flue gas temperature:
Operational type:
«Intermittent combustion» here means normal use of a fireplace,
i.e. to continue producing heat, add more fuel as soon as the
previous load of wood has burnt down to embers.
eNglish
45 kg
120 kg
cross section
2
1777 mm
473 mm
488 mm
600 mm
1425 mm
1223 mm
See fig. 1A+1B
See pkt. 6.0
5,5 kW
5,9 g/s
73 % @ 5,8 kW
0,12 %
330
C
o
Intermittent
11

Publicité

loading