wall & Floor Fixing
The President FS can be installed against a wall or in the room away from walls. The appliance is designed to
be fixed to the floor. The appliance can additionally or alternatively be fixed to a rear wall. The fixing positions
are shown in figure below. The appliance is approved for installation directly on wood flooring. If the appliance is
installed directly on carpeting, vinyl tile or other combustible material other than wood flooring, it must be installed on
a metal or wood panel extending the full width and depth of the appliance.
Floor requirements
The 530 heater is approved for installation directly on any combustible material other than soft flooring material such
as carpet or vinyl.
Mantel requirements
The President FS may be installed with a combustible mantel provided clearances are maintained as indicated in
the Dimensions and Clearances. Be aware that although safe, some combustible materials and finishes at the listed
clearances may, over time, discolor, warp, or show cracks. Care should be taken when choosing materials—consult
your fireplace dealer.
Dimensions & Clearances
24-1/2" (620 mm)
WALL
3-3/4" (95 mm)
from upper
25-1/2"
fixing points to
(648 mm)
center of rear
vent pipe
7-1/2"
(190 mm)
9-7/8"
(250 mm)
FLOOR
Ceiling
36"
(914 mm)
min.
36" (914 mm)
min. to
combustibles
Appliance
outline
Center line
of appliance
Fixing
points
See table
A
Mantel
Spacers for
combustible
B
walls (1-1/4" thick)
min. from
casting Top
Mantel Depth "a"
Up to 7"
Above 7" up to 8"
Above 8" up to 9"
Above 9" up to 10"
Above 10" up to 12"
More than 1"
Mantel leg
Projection "D"
Up to 8"
More than 8"
E
13-1/4" (336 mm)
1-1/4"
(32 mm)
to wall
Allow
more
space as
necessary
for venting
components
1-1/4"
(32 mm)
min. from
casting Top
to wall
Min. Clearance "b"
4"
5"
7"
8"
9"
9" +extra 1" for every 1"
depth above 12"
Min. Clearance from
appliance side "e"
0"
6"
Mantel leg
- see
table
D