Télécharger Imprimer la page

Telcoma STEALTH Instructions Pour L'utilisation Et La Programmation page 48

Motoréducteurs à bras articulé pour portails battants

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
GB
4a
M1
4b
M1
5
M1
6a
PROG.
P3
P/P
STOP
For EVOLVED PROGRAMMING (with change in time lag and deceleration times),after step (3D) proceed as follows:
4a
M1
4b
M1
5
M1
6a
PROG.
P3
P/P
STOP
47
No other references are required in STANDARD programming; M1 opens automatically until
the opening limit stop is detected.
Then M2 starts opening and when it has reached the opening limit stop, storage of the pause
time starts (if automatic reclosing is not used, go directly to step(6a).
M2
M2
When the desired pause time has elapsed, press button P/P; the gates close one at a time, first
M2 and then M1.
When the gate leaves are fully closed, the control unit exits from programming.
Check: thrust, times and stopping points. Repeat programming after any change to the
M2
mechanical stops.
6b
LD1
M1
When M1 has completed the closing movement, it stops and then reopens automatically;
during opening, press button P/P when M1 has reached the desired time lag.
The control unit stores the delay time between opening of M1 and M2; the motor stops for a
moment and then restarts.
M2
You can also set the point where you want the gate leaf to start deceleration during the opening
movement or wait for full opening.
After M1 has opened, M2 opens; also in this case you can set the point where you want
deceleration to start or wait for full opening of the gate leaf. At the end of this movement, storage
of the pause time starts (if automatic reclosing is not used, go directly to step (6a).
M2
When the desired pause time has elapsed, press button P/P; the gates close one at a time. M2
starts and during closing, press button P/P to give the desired point of time lag. The control unit
stores the delay time between closing of M2 and M1; the motor stops for a moment and then
restarts.
You can also set the point where you want the gate leaf to start deceleration during the closing
M2
movement or wait for complete closing. After M1has closed, M2 closes; also in this case you
can set the point where you want deceleration to start or wait for the gate leaf to be fully closed.
When the control unit acknowledges the closing of both gate leaves, it automatically exits from
programming.
Check: thrust, times and stopping points. Repeat programming after any change to the
mechanical stops.
6b
LD1
M1
6c
M2
M1
6c
M2
M1
6d
M2
M1
FINE PROG.
6d
M2
M1
FINE PROG.
M2
M2

Publicité

loading