The impression can be copper-plated or silver-
plated.
Storage of the impression
▸ Store at room temperature (15 – 25 °C/59 – 77 °F)
in a dry place!
▸ Protect against exposure to direct sunlight!
The impression is stable and can be cast even
after months without loss of accuracy.
Technical data
Honigum-Light
Working time
[min]
1
Intraoral setting time
Dimensional change after
24 h [%]
Compression set [%]
Shore-A hardness
Fast
≤ 2:15 ≤ 1:30
[min]
≥ 3:30 ≥ 2:00
2
≤ 0.5
≤ 0.5
≤ 0.35 ≤ 0.35
≈ 47
≈ 47
Honigum-Light
Strain in compression [%]
The time stated applies at a room temperature of 23 °C and
1
a normal relative air humidity of 50%. Higher temperatures
shorten, lower temperatures increase these times.
The working time describes the period from the start of mix-
ing until the time by which the tray must be positioned in the
patient's mouth.
The times indicated apply from the start of mixing for a tem-
2
perature of 35 °C.
Disinfection of the Automix-
Dispenser
The Automix-Dispenser is reusable after disin-
fection, although it should be replaced if visible
signs of wear appear.
Disinfection can be carried out using a commer-
cially available dipping disinfectant. DMG rec-
ommends using only disinfecting solutions list-
ed by the RKI (Robert Koch Institute). The
Automix-Dispenser is also autoclavable.
Fast
≈4.5
≈3.9