Pool Water Chemistry; Installation Instructions - Bestway Flowclear 58215 Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PICTURE
1
2
8
9
REF. NO.
PARTS NO.
DESCRIPTION
1
P6488
Electrolytic Cell
2
P6369
Connecting Hose
3
P6489
Water Flow Sensor
4
P6371
Gasket
5
P6372
Screw
Adaptor E ( For connection to filter
6
P6375
pumps with 1-1/4in.(32mm) hose size)
Adaptor F ( For connection to filter
7
P6376
pumps with 1-1/4in.(32mm) hose size)
8
Adaptor A
F6H184
9
Adaptor B

POOL WATER CHEMISTRY

Optimum Pool Water Chemistry Conditions
It is recommended that the following pool water chemistry
conditions should be maintained to help protect pool users.
The chlorinator is warranted to operate properly only if below
conditions are met.
Minimum
Free Chlorine
0
Combined Chlorine
0
pH
7.2
Total Alkalinity
100ppm
Calcium Hardness
150ppm
Stabilizer (Cyanuric Acid)
10ppm
Pool Salt Usage
Use only sodium chloride (NaCl) salt that is at least 99.8% pure.
The ideal salt level in the pool water is between 2000~3000ppm
(parts per million).
Water Capacity (Calculated at
90% for Frame Pool and 80%
Salt Needed for Startup
For Fast Set & Oval Pool)
Gallons
Liters
Lbs
7500
42
2000
15000
85
4000
22500
130
6000
30000
170
8000
37500
210
10000
45500
255
12000
53000
300
14000
3
4
5
6
7
Ideal
Maximum
1.0-3.0ppm
3.0ppm
0
0.2ppm
7.4 - 7.6
7.8
100 - 140ppm
140ppm
200 - 400ppm
500 - 1000ppm
30 - 50ppm
150ppm
Salt Needed when Low Salt
Detected
Kgs
Lbs
20
15
6
40
25
10
60
40
20
75
55
25
95
65
30
115
80
35
135
95
40
Salt Calculation for Pools
Salt Needed for Startup
Lbs
Water Capacity
(Gallons) x 0.0375
Operating Time Reference
Water Capacity
Gallons
Liters
2000
4000
15000
6000
22500
8000
30000
10000
37500
12000
45500
14000
53000
QTY.

INSTALLATION INSTRUCTIONS

1
NOTE: The preferred installation is that the chlorinator must be
1
installed as the last piece of pool equipment in the return line to
(100cm)
the pool. This will extend the life of the titanium plates and
1
maintain its performance.
1. If your above ground pool is filled with water, remove the
1
debris screens from the inside of the pool and insert the
1
stopper plugs in the pool's inlet and outlet valves before the
chlorinator installation (or close the control valves), which will
1
prevent water from flowing out of the pool. Jump to step 2
directly if your pool is empty.
1
2. Connect the adaptor F to the electrolytic cell outlet and screw
the threaded locking ring into position.
1
3. Disconnect the water return (to the pool) hose from the filter
1
pump connection, and connect this hose to the adaptor F with
a hose clamp.
4. Connect the adaptor E to the filter pump outlet and screw the
threaded locking ring into position.
5. Connect the connecting hose to the adaptor E and screw the
threaded locking ring into position.
6. Remove the stopper plugs and insert the debris screens (or
open the control valves) to allow water to flow.
For connection to filter pumps with 1-1/4in. (32mm) hose
(with hose clamps):
A
Connecting Hose
Kgs
Adaptor F
4
Salt Needed when Low Salt Detected
Kgs
Lbs
Water Capacity
Water Capacity
(Liters) x 0.0045
(Gallons) x 0.0067
Operating Time (hours) at different
ambient/air temperatures
10-19°C
20-28°C
(50-66°F)
(68-82°F)
7500
1
1
2
2
2
4
4
6
4
6
6
8
6
8
Pool
B
Filter
Pump
Kgs
Water Capacity
(Liters) x 0.0008
29-35°C
(84-95°F)
2
4
6
8
8
10
10
Adaptor E
S-S-004379

Publicité

Table des Matières
loading