Programming the total opening code (Mot 1 + Mot 2):
• Position yourself with the SELECT button on the flashing light of LED L3;
• Press SET once, the LED will change its flashing (1 0 1 0 longer),
indicating that it is saving the first level;
• Send the preselected code by pressing the key to be configured with
the desired remote control;
• LED L3 (TX CODE) will remain lit (fixed) for a few seconds, indicating that
programming is complete;
• LED L3 (TX CODE) will start flashing again for another 10 seconds,
waiting for a new code to be saved;
• Once these 10 seconds have also lapsed, LED L3 will remain lit (fixed).
Send the selected code with the remote control (Mot. no. 1):
• Position yourself with the SELECT button on the flashing light of LED L3
(TX CODE);
• Press SET twice consecutively, the LED will change its flashing (1 1 0 1
1 0), indicating that it is saving the pedestrian code;
• Send the preselected code by pressing the key to be configured with
the desired remote control;
• LED L3 CODE will remain lit for a few seconds, indicating that
programming is complete. The extra 10 seconds allow additional PPED
codes to be saved, after which it will remain active as described above.
Important note: If all 120 codes have been saved, when the programming
operation is repeated, all programming LEDs will start to flash, indicating that
no additional codes can be saved.
Deletion of remote control codes:
• By the key SELECT, position yourself on the blinking LED L3 "CODE TX";
• Activate the blinking of the code to be deleted (P.P. or PED., indicated by
the respective blinking);
• Press and hold down key SET for more than 5 sec.;
• The LED switches off for 2 sec. and the procedure is completed.
• If all the codes, both for CODES and PASSAGES are eliminated, the
LED will remain turned off.
CAUTION: If only PEDESTRIAN codes are saved, the LED will
flash differently (1 1 1 1 0 1 1 1 1 0).
Rule of the first saved Remote control:
When programming remotes the following rule is applied:
if the first remote to be saved is a rolling code type, the receiver will
subsequently accept only rolling code remotes (thus providing enhanced
anti-intrusion security); if the first remote to be saved is a fixed code type,
the receiver will subsequently accept both fixed code remotes and rolling
code remotes, although only the fixed part of the latter will be controlled
(thus effectively relinquishing the security of the rolling code system).
8.1.4 LED L4 - CONDO: "Condominium" logic:
The enabling of the Condominium function means that during the opening
movement or during the pause time the control unit will not respond to
commands sent by Pushbuttons or remotes.
In contrast, during the closing movement a command sent by the
Pushbuttons or the remotes will reverse the direction of movement. This
operating mode is invaluable when the automation includes a loop detector.
In the default configuration the control unit is set with the Condominium
function disabled; if the Condominium function is required, proceed as
follows:
• By the key SELECT, position yourself on the blinking LED no.4;
• Press the SET key;
• LED L4 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.1.5 LED L5 - MOTOR TIME: Programming of the motors stroke (max 4
min.)
The control unit is factory set with a motor time of 30 seconds without
deceleration.
To set a new stroke, programming must be carried out with leaves in closed
position as follows:
• By the key SELECT, position yourself on the blinking LED no.5;
• Press the SET key; · Motor no.1 starts the opening phase;
• When the desired deceleration starting point is reached press the SET
key (the leaf continues its stroke at a decelerated speed);
• Press SET key to determinate the opening end stop;
32
COMUNELLO ®Copyright 2021 - All rights reserved
• At this point Motor no.2 starts to open the second leaf;
Repeat the work time programming procedure for Motor 2;
Once programming of the motor Opening times has been completed,
Motor 2 immediately restarts in Closing: repeat the above procedures for
the Closing phase of Motor 2 and subsequently of Motor 1.
Important notes: If you do not require the control unit to perform the
deceleration, during programming, when the open-close cycle has been
completed press the SET key twice consecutively rather than just once.
During programming, instead of the SET key on the control unit you can use
the button on the remote already stored. (see section 7.1.3.).
8.1.6 LED L6 - PAUSE TIME Automatic closing time programming:
The control unit is factory set with automatic closing disabled.
If you wish to enable automatic closing proceed as follows:
• By the key SELECT, position yourself on the blinking LED no.6;
• Press the SET key;
• Wait for a time equivalent to the desired time interval (from 1 sec. up to
4 min.);
• Press the SET key again momentarily and at the same time the automatic
closing time will be saved and LED L6 will remain steady on;
If you want to restore the initial condition and disable the automatic closure,
proceed as follows:
• Position yourself on the flashing light of LED L6;
• Press twice consecutively the SET button in a time interval of 2 seconds;
• The LED will turn off and the operation will be completed.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand.
8.1.7 LED L7 - PED. TIME: Programming the pedestrian work time:
The control unit is supplied by the manufacturer with a preset Motor no.1
(Pedestrian) work time equal to 10 seconds and without deceleration
(programmable up to a maximum of 4 minutes).
If it is necessary to modify the pedestrian work time, the programming has to
be carried out with the shutter closed in the following manner:
• Position yourself with the SELECT button on the flashing light of LED L7;
• Momentarily press the SET button;
• The Motor will start the Opening cycle;
• In correspondence with the desired start point of deceleration, once
again press the SET button;
• LED L7 will start to flash more slowly and the Motor will decelerate;
• When the desired position is reached, press the SET button to complete
the Opening cycle;
• LED L7 will flash again normally and the motor will restart in Closing;
• Repeat the procedures described above for the Closing phase.
Deceleration cycle is set automatically too at approximately 15% of the
complete cycle.
If you do not want the control unit to perform the deceleration, during
programming, at the completion of the opening and closing cycle, press
the SET button twice consecutively instead of only once.
During programming, the remote control button (only if previously