To do so, pull the stopper (7) out of the drain hose (11)
and drain off the liquid. Then insert the stopper (7)
again.
9.
Maintenance and cleaning
m WARNING!
Prior to any adjustment, maintenance or service work
disconnect the mains power plug!
Cleaning
It is recommended to clean the device after each use.
Do not spray the device with water or clean it under
running water. This can result in electric shocks and
can damage the device.
Empty the stainless steel container (15) after each
use: After opening the stopper in the drain hose (7),
the liquid collected can be drained out. Residual liq-
uid remains in the stainless steel container (15). To re-
move residual liquid, take off the machine head (2) by
releasing the locking hooks (5) from the stainless steel
container (15). Pour out the liquid residue. Clean the
container with a damp cloth.
• Replace paper filter bag when full
• Always keep the device clean. Do not use cleaning
agents or solvents.
• Keep the ventilation slots clean and free of dirt and
dust.
• Clean the device only with a soft brush or a damp
cloth.
• Clean the foam filter (22) with a little soap and run-
ning water and then leave it to air dry.
Maintenance
The device is maintenance-free.
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consuma-
bles. Wear parts*: Foam filter, Paper filter bag, Folded
filter for dry vacuuming
* Not necessarily included in the scope of delivery!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
10. Storage
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
• There are recesses in the wheel mounting base (10)
at the rear of the machine and on the machine head
(2) for storing the floor nozzle (25), the joint nozzle
(26) and the metal extension tube (27).
• The mains cable (3) can be wound around the push
grip (4). (Fig. 21)
11. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
www.scheppach.com