IV. GETTING STARTED
4.1- Unpacking
- Remove product from its packaging.
- Check that tool and accessories are not damaged.
4.2- Assembly
Connecting the evacuation hose (Fig.1)
Wedge the discharge hose on to the pump output (5).
Add a fixing collar (hose clamp not supplied) to complete the seal.
Check the assembly.
Installation
Note: Before use, clear the outlet line
Observe and respect minimum water level and max delivery height
1. The pump must be in a vertical position: ensure that it is stable during operation.
2. Hang the pump on the carrying handle with appropriate rope or wire cable or place the pump on
the bottom of the well, pond or vessel. Never hang the pump by the electric cable or discharge hose.
3. The suction holes must never be obstructed. It is therefore preferable that the pump should never
be placed directly on the ground or on the bottom of the well, pond or vessel.
For example, use a brick to support the pump.
Warning: to dry out premises (cellar draining for example) it will be necessary to place the pump
below floor level.
4. The battery box is fitted with 4 mounting feet (8) to allow permanent mounting on adequate
support.
4.3- Battery and charger
NOTE: this model PRBAT20/PVCSB is supplied WITHOUT battery and charger.
To insert and remove the battery (Fig.3)
a) To insert the battery:
Open the cover (7) and slide the battery [a] into the compartment.
Make sure that the battery is securely locked.
Close the cover (7).
b) To remove the battery:
Open the cover (7).
Press the release button [b] and pull battery out of the compartment.
Fig.3
Tips to ensure optimal battery life:
- Do not to drop, hit, or damage the battery.
- Recharge the battery before it is completely drained.
When you notice that the pump performance is decreasing, recharge the battery accordingly.
- Never charge a fully charged battery. Overloading reduces its life.
- If the battery is hot, allow it to cool down before proceeding with charging.
- When the product is not used, it is recommended to charge the battery every 3 months.
4.4- Starting (Fig.2)
- Switching on: Set the switch (9) to position "I".
- Switching off: Set the switch (9) to position "0".
Page 32 / 38