• MAXIMUM POWER
o turn the switch to D: lamp (6) lights on.
Warning
When in heating mode, the fan starts only after
heating resistances have been heated sufficiently, to
prevent cold air is blown.
• SWITCHING OFF
o turn the switch to A: lamp (6) lights off.
Warning
This model is equipped with a cooling ventilation
after switching off: the fan stops only after heating
resistances have been cooled down sufficiently.
Wait until the residual heat is completely dissipated
before switching off the heater and removing it or
disposing any object in the vicinity.
ROOM THERMOSTAT
Operation will only be automatic if a thermostat or another
control device is connected to the thermostat plug (3):
• Take the plug (3) out of the power switchboard, open it and
remove the electrical jumper between terminals 2 and 3 of the
plug.
• Connect the thermostat electrical cable to terminals 2 and 3 of
the thermostat plug (3).
• Close the plug again and plug it back into the power
switchboard.
By setting the room thermostat at the desired temperature level,
the heater will start and stop automatically. When the selected
temperature level is reached, the fan only goes on for some time.
OBSERVED FAULTS, POSSIBLE CAUSES AND REMEDIES
OBSERVED FAULT
• The fan doesn't start
• The fan starts but there is not enough heat
• The space heaters stops
EN
SAFETY THERMOSTAT MANUAL RESET
overheating. If the thermostat releases, disconnect fan electricity,
wait until the fan has cooled and fix the problem causing
overheating.
press the switch (5).
MANTEINANCE
Warning
CLEANING
carried out regularly. Dust and dirt may result in overheating and
fire.
DISPOSAL
product by taking it to a local differentiated waste collection center
in conformity to law.
if it has the symbol, it means that disposal is regulated by EU
Directive 2003/96 (Waste Electrical and Electronic Equipment,
WAEE).
waste collection system and follow its instructions.
seriously harm the environment and health and is subject to
administrative penalties.
CAUSE
• No electrical current
• Winding of motor burnt or interrupted
• Wrong setting of room thermostat
• Defective room thermostat
• Safety thermostat intervenes
11
A temperature-limit thermostat will stop power feeding in case of
To reset the temperature-limit thermostat, remove the cover and
Before carrying out any maintenance operation you
must:
• Stop the heater;
• Turn off the disconnecting switch on the electric
switchboard;
• Wait until the heater has cooled down.
For the heater to operate efficiently, cleaning operations must be
At the end of its useful life, you have to scrap and dispose of this
Before scrapping, check the serial number plate on the machine:
The user must inquire about the local electrical and electronic
Illegal disposal of this product with normal domestic waste can
• Check mains, it should be
• Check proper positioning and functioning of
switch
• Replace motor
• Check correct setting of room thermostat
• Replace room thermostat
• Identify the problem that caused the
overheating
REMEDY