►►►7. SWITCH-ON
en
it
►►7.1. HEATING MODE:
►7.1.1.Turn the "O/I" switch to position "I"
de
(Fig. 18).
es
►7.1.2.Wait a few seconds.
►7.1.3.Press the gas button fully home and
fr
hold it down (Fig. 19).
►7.1.4.Activate the piezoelectric igniter fully
nl
home and repeatedly (Fig. 20), keeping the
pt
gas button pressed (Fig. 19).
►7.1.5.After ignition of the flame, hold the gas
da
button down for about 15 s (Fig. 21).
fi
►7.1.6.Release the gas button (Fig. 22).
In the event of a power cut or if there is no gas
no
supply, the heater will switch off. The heater
sv
does not switch back on automatically. It must
be switched on manually by repeating the
pl
switch-on procedure. If the heater does not
switch on, consult the relative section (Par.
ru
"12. TROUBLESHOOTING").
cs
►►7.2. VENTILATION MODE:
hu
The heater can also be used as a fan. Connect
sl
the generator to the mains electricity and/or
insert the rechargeable battery and turn the
tr
"O/I" switch to position "I" (Fig. 18).
hr
PLEASE NOTE: With the heater functioning
in heating mode, before passing to
lt
ventilation mode, carry out the correct
lv
switch off sequence (Par. "9. SWITCH-
OFF").
et
ro
►►►8. HEAT CAPACITY
sk
REGULATION
The heat capacity can be regulated with the
bg
knob positioned on the base of the heater
uk
(Fig. 23).
bs
el
►►►9. SWITCH-OFF
►9.1.Close the gas cylinder (Fig. 24).
zh
►9.2.Leave the fan to cool for about 60 s,
in order to prevent internal damage due to
overheating (heater internal cooling).
►9.3.Turn the "O/I" switch to position "O" (Fig.
25).
►9.4.Disconnect the heater from the mains
power supply (Fig. 26) and/or remove the
rechargeable battery from the mains or
disconnect the battery (Fig. 27).
►9.5.Disconnect the heater from the gas
supply pipe (Fig. 28-29-30).
►►►10. CLEANING AND
MAINTENANCE
Ask the technical support service to check that
the heater is working properly at least once a
year and/or as required. The heater must be
cleaned before it is put away after use.
►10.1.Before starting any type of maintenance,
care and repairs of the heater, carry out the
switch-off sequence (Par. "9. SWITCH-OFF").
►10.2.Cleaning only concerns the air vent
(rear side) of the heater.
►10.3.When the heater is used again, check
the condition of the gas hose. If in doubt
regarding its condition, request assistance
from the technical after-sales service.
►10.4.Do not carry out any unauthorised
maintenance.
►►►11. STORAGE AND TRANSPORT
OF THE BATTERY
DO NOT KEEP AND STORE THE BATTERY
AT A LOW TEMPERATURE FOR A LONG
PERIOD OF TIME.
The Li-ion rechargeable batteries are subject
to the Dangerous Goods Regulations. The
user can transport the rechargeable batteries
by road without taking additional precautions.
In third party transportation case (e.g. by air
and/or freight forwarder), must be observed
the requirements according to the all local
regulations and standards in force. Ship the
rechargeable batteries only if their shell is not
damaged. Cover the exposed contacts with
adhesive tape and pack the rechargeable
battery in such a way that it cannot move in
its packaging. Please also observe any other
applicable domestic standards.