Technical data sheet
Commercial dishwasher
Legend:
Electrical
1. Voltage (standard version)
connection
Variations in the following countries:
2. Voltage (standard version)
3. Voltage (standard version)
Installation PG 8055
08.12.2015
Circled, bold-type abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Connected load
Fuse rating
Connection cable, min. gauge
Connection cable length (H05(07)RN-F) without
plug
Voltage
Connected load
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
plug
Connected load
Fuse rating
Connection cable, min. gauge
Connection cable length (H05(07)RN-F) without
plug
Voltage
Connected load
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
plug
Connected load
Fuse rating
Connection cable, min. gauge
Connection cable length (H05(07)RN-F) without
plug
Voltage
Connected load
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
plug
PG 8055
GB
V/Hz
3N AC 400/50
kW
8.9
A
3 × 16
mm²
5 × 2.5
m
Approx. 1.7
V/Hz
AC 230/50
kW
3.4
A
16
mm²
3 × 1.5
m
Approx. 2.1
V/Hz
3 AC 230/50
kW
7.1
A
3 x 20
mm²
4 x 2.5
m
Approx. 1.7
V/Hz
AC 230/50
kW
3.4
A
16
mm²
3 × 1.5
m
Approx. 2.1
V/Hz
3N AC 400/50
kW
7.1
A
3 × 16
mm²
5 × 2.5
m
Approx. 1.7
V/Hz
AC 230/50
kW
3.4
A
16
mm²
3 × 1.5
m
Approx. 2.1